Download presentation
Presentation is loading. Please wait.
Published bySydney Barnett Modified over 8 years ago
1
1 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Dishwasher Wash System Upgrade Benefits Sound Reduction Less Water Consumption Improved Drying Energy Savings New Components Control Motor Drain Pump Wash Arms Pump Adapter Drain Hose All stainless steel tubs 6000 series and up Includes Monogram
2
2 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Benefits Sound Reduction - An average sound reduction of 2db is achieved by moving less water through the wash system (15 gallons per minute versus the current 24 gallons per minute) and isolating the drain pump by placing an adapter between the sump and the pump. Less Water Consumption – The tub fills with an average of 1.3 gallons per fill versus the current 1.5 gallons. The water valve is energized for less time (60-62 seconds versus the current 70-75 seconds). Savings per wash cycle is approximately 1.4 gallons on a 7 fill cycle. Improved Drying – The electronic control increases heater on-time during the final rinse on all models. PDW8600 and below models add 8 minutes to the heated dry cycle for a total of 38 minutes dry time. Energy Savings – Internal testing shows an energy savings, although the energy labels will not be changed at this time.
3
3 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE New Components Drain Pump Electronic Control Adapter Coupling Motor Wash Arms Drain Hose
4
4 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Adapter The adapter isolates the drain pump from the sump and contributes greatly to the reduction in sound levels.
5
5 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Adapter Components The adapter is available as a complete assembly or as individual parts.
6
6 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Adapter Coupling
7
7 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Adapter Coupling
8
8 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE
9
9 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Drain Pump Mounting
10
10 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE
11
11 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Drain Hose
12
12 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Two Down Jets 10 Jets on top of arm Jets randomly spaced both sides of arm All jets are oblong Jet diameters range from.160” to.240” Jet diameters ~.250” Current Design Upper Mid Lower All jets are circular 3 outside jet diameters =.190” 6 inside jet diameters =.130” 9 Jets on top of arm 4 jets lined up 1.25” apart Jet diameters ~.125” No Down Jets New Design Upper Mid Lower
13
13 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE
14
14 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Motor
15
15 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Impeller Current Impeller New Impeller Design
16
16 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE
17
17 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE 2 ¾” Minimum Water Level
18
18 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Minimum water level to edge of left side heater support