HQ02 Magnetic Measurements Prelim. Results Overview 28Jun2013
2
Summary of Magnetic Measurements Performed on HQ02 A – 200mm and 100mm long PCB probe ( simultaneous acquisition of both circuits ) B – dual 100mm long PCB probe ( simultaneous acquisition of both circuits ) C – 100mm long Tangential probe
3
Z-scans 2K 964A 14605A scans repeat well 8500 14605 Saturation effect Zscans on upramp and downramp show stable persistent current magnetization vs. z
4
Changes in b3/a3 vs Z-position are ~5 units in the straight section - indicating some variations in coil geometry b6 change is ~2 units
5
From standard deviation of harmonics in the magnet straight section, can calculate amplitude of coil block variations from HQ02 cross-section error fit. 48 m axial coil position variation is larger than TQ or HQ01 which were closer to ~30 m
6
Apply same technique among the three assemblies HQ01d, HQ01, and HQ02 Coil position variation is ~ 62 m TQ series had ensemble variation of ~140 m Courtesy XRW
7
Accelerator profile reproducibility test
8
Accelerator profile injection porch b6 decay and snap-back About 0.5 units b6 change over 20 min.
9
Ramp up from 50A 300A 600A 900A Accelerator Cycle Reset Current Test
10
Loops at 20, 40, 80A/s ramp rates at 3 different z-positions b6 has very comparable shape for all three positions a3 has some small differences especially in the -0.2m position
11
Loops at 20, 40, 80A/s ramp rates at 2K and 4K temperatures (I’ll improve the plots from what’s shown here…)
12
Perhaps a slide on the coil imbalance tests ?