School of Biomedical Engineering, Science and Health Systems APPLICATION OF WAVELET BASED FUSION TECHNIQUES TO PHYSIOLOGICAL MONITORING Han C. Ryoo, Leonid Hrebien Hun H. Sun School of Biomedical Engineering, Science and Health Systems Drexel University, Philadelphia PA. 19104 February 10, 2001
3
School of Biomedical Engineering, Science and Health Systems Motivation 1. High rates of false alarm in current monitoring systems 2. Very little research on physiological state monitoring by signal-level data fusion 3. Difficulties to realize fusion system due to observations often dependent from sensor to sensor in practical cases 4. No research about which fusion criterion is optimal under various input statistics - why or when ? 5. Lack of unifying rule to find optimal combination of local thresholds
4
School of Biomedical Engineering, Science and Health Systems Binary Decision Problems S ( k ) : samples of input signal n ( k ) : additive noise, Cost function CF = C 00 P(accept H 0, H 0 true) + C 01 P(accept H 0, H 1 true) + C 10 P(accept H 1, H 0 true) + C 11 P(accept H 1, H 1 true)
5
School of Biomedical Engineering, Science and Health Systems Likelihood Ratio Test and Minimal Error Criterion Likelihood Ratio Test Minimum error criterion C 00 = C 11 = 0 C 10 = C 01 = 1 , Multi-Sensor (distributed) Fusion Systems 1. Fixed fusion rule --> optimal local threshold ? 2. Fixed local threshold --> Optimal fusion rule ? 3. Varying fusion rule --> varying local threshold ? Applying various fusion rules to all subjects - not possible We fix fusion rule and operate it optimally Typical issues in fusion systems
6
School of Biomedical Engineering, Science and Health Systems Problems of General Fusion Theory applied to Biological Signals Heavy constraints : the same volume of observations and identical statistics Little work on nonstationary (biological) signals No comparative data from real biological phenomena Analytical work and numerical simulations nonidentical statistics and individual differences in human physiology Which fusion rule and why optimal ?
7
School of Biomedical Engineering, Science and Health Systems Wavelet Transform Method f (t) : input signal, j, k : dilation (Scale) and translation index : orthonormal scaling and wavelet filter coefficients related by orthogonality W : details or wavelet coefficients = DWT A : Approximation Sampling Frequency = 1000 Hz Time-Frequency (time-scale) Description - j time Scale j j = 1 j = 2 j = 3 j = 4
8
School of Biomedical Engineering, Science and Health Systems Wavelet Combined Fusion System Source (H 0,H 1 ) DWT Data Fusion Center (DFC) Transient Features Local Decisions (LD) LD Global Decisions (GD) Fusion Criterion Optimal operating points
9
School of Biomedical Engineering, Science and Health Systems Probability density function for Chi-square and Gamma distribution Degree of Freedom 1 2 4 8 16 Variance 12481248 With different degrees of freedom (DOF) Different variances with DOF=3
10
School of Biomedical Engineering, Science and Health Systems Indices of System performance at local detectors and Fusion center Receiver Operating Characteristics (ROC) Smooting in Scale Log Likelihood Ratio Probability of detection and false alarm DOF increases
11
School of Biomedical Engineering, Science and Health Systems Probability density function (PDF) of linearly combined powers Powers Conditional density function for Respiration, Blood Pressure and EEG
12
School of Biomedical Engineering, Science and Health Systems Powers and Local Thresholds under ROR and GOR runs
13
School of Biomedical Engineering, Science and Health Systems Powers and Local Thresholds under Flight Run
14
School of Biomedical Engineering, Science and Health Systems Local and Global Decisions
15
School of Biomedical Engineering, Science and Health Systems Receiver Operating Characteristics (ROC) Analysis Respiration Blood Pressure EEG Respiration Blood Pressure EEG max(P F ) when P D =1 min(P F ) when P D =1
16
School of Biomedical Engineering, Science and Health Systems Results : Numerical False Alarm (FA) at Local Sensors and Data Fusion Center (DFC) (SE : Standard Error, All units are in %) False Alarm Reduction : 10- 38 % during ROR/GOR Profiles 25-35 % during Flight Run 21-36 % During Overall Run
17
School of Biomedical Engineering, Science and Health Systems Conclusion Our fusion system, a combination of wavelet transform and general fusion system, gives significant improvement in system performance for physiological state monitoring Minimum error criterion - optimal fusion rule for different variable statistics - can be realized by a combination of AND and OR rule - robust to sensor failure No harm with more number of poor local detectors A unifying rule to find optimal combinations of local thresholds are adaptively applied to all subjects Identical detectors are employed to process complex biological signals containing various features
18
School of Biomedical Engineering, Science and Health Systems Recommendation for Future Works Other fusion criteria need to be tried – which criterion and why optimal ? Conditions to operate fusion system optimally has to be found under various input statistics