Presentation is loading. Please wait.

Presentation is loading. Please wait.

Digital Micromirror Device Begon Martin Ciapala Richard Deaki Zoltan Reliability of MEMS: Case study January 30th 2007.

Similar presentations


Presentation on theme: "Digital Micromirror Device Begon Martin Ciapala Richard Deaki Zoltan Reliability of MEMS: Case study January 30th 2007."— Presentation transcript:

1 Digital Micromirror Device Begon Martin Ciapala Richard Deaki Zoltan Reliability of MEMS: Case study January 30th 2007

2 What is a DMD ? Matrix of micromirrors 1024 x 768 mirrors for example Size of the mirrors: 16 x 16 um

3 What is a DMD ?

4

5 Applications Mainly projection systems (Digital Light Processing) Other emerging applications such as 3D metrology, confocal microscopy,digital TV

6 Hinge fatigue Fatigue: slow growth of a crack driven by repeated plastic deformation Mirror in normal operating mode switches every 200 microseconds 5 years use with 1000 operating hours a year  mirrors switch 90x10 9 times

7 Hinge fatigue First approach: anaylsis using bulk properties of the hinge material  showed that fatigue would be a big problem However… accelerated tests proved that wrong, samples easily exceeding 100x10 9 switches showing no fatigue. Explanation: hinge so thin  governed by thin film properties!


Download ppt "Digital Micromirror Device Begon Martin Ciapala Richard Deaki Zoltan Reliability of MEMS: Case study January 30th 2007."