The Apparatus…. Ionic target studies…. Neutral target studies…. Queens University Belfast University College London.

Similar presentations


Presentation on theme: "The Apparatus…. Ionic target studies…. Neutral target studies…. Queens University Belfast University College London."— Presentation transcript:

1 The Apparatus…. Ionic target studies…. Neutral target studies…. Queens University Belfast University College London

2 Ion Source -ions produced via discharge Extraction and Focussing Lenses - ions are accelerated to 1-2 keV Selection Magnet Einzel lens Deflection Plates Interaction Region 45 o Parallel Plate deflectors Neutral Fragment Detector Primary Beam Collector Charged Fragment Detector Schematic of the Ion Beam Apparatus Laser Beam

3 Plasma Discharge Ion Source In the fringe region between the anode and cathode, electrons are stripped off the introduced gas by the strong electric field. The electrons then spiral due to the surrounding magnetic field thus colliding with more atoms ionizing them. The ions produced are self-extracted through the aperture due to the electric field distribution and are then focused and transported. - creates a plasma of ions and electrons

4 Mass Selection Magnet - used to select the particular ion species to study. Ions passing through the magnet field region are deflected due to the Lorentz force. For a particular magnetic field setting, ions of different mass/charge ratios are deflected through different angles. By varying the magnet field we can select a particular mass/charge ratio ion to exit through the final aperture.

5 Interaction Region - interaction of ions with focused laser beam. The laser system used is the RAL Astra 790nm Ti:Sapphire laser giving 50fs, 25mJ pulses at 10Hz.RAL Astra 790nm Ti:Sapphire laser When focused with a relatively soft focusing lens, we obtain intensities between 10 16 – 10 17 Wcm -2. The ionized ions are carried along with the initial momentum of the primary ion beam. A set of plates can also be used to bias the interaction region if needed.

6 Parallel Plate Analyser - used to separate product ions from primary ion beam. An electric field is applied across the 45 o parallel-plate region. Ions of higher charge/mass ratio are deflected more by the electric field thus one can separate out the ionized products from the primary ion beam. The main ion beam is dumped in a well-baffled Faraday cup whilst the product ions are detected by a CEM. An on-axis CEM is used to detect any neutral fragments from molecular studies.

7 Focussed Laser Beam Neutral Target Apparatus The gas is effused into the interaction region via a hypodermic needle. The focused laser interacts with the gas target and the product ions are extracted by a weak electric field across the interaction region. After drifting up the drift-tube region, the product ions are detected by a pair of microchannel plates with their time-of-flight recorded. The system can be operated in Spatially-resolved geometry mode or Wiley-McLaren mode.

8 z x y focussed laser direction ion beam direction Scanning Techniques…. Intensity Scan With the Intensity scan, interact the ion beam with the centre of the laser focus. Then vary the peak focus intensity by varying the input power of the laser. Thus measure Ion yield (ionization) as a function of laser intensity.

9 Scanning Techniques…. Intensity Selective Scan With the Intensity Selective Scan, drive the laser focus through the ion beam. By interacting with different intensity slices of the focus, we again measure the Ion yield as a function of intensity. This technique has the added advantage in that the low intensity regions are enhanced by increased volume. z x y focussed laser direction ion beam direction


Download ppt "The Apparatus…. Ionic target studies…. Neutral target studies…. Queens University Belfast University College London."