Download presentation
Presentation is loading. Please wait.
Published byCharlene Helena Heath Modified over 9 years ago
1
1 Calorimetry W-Scintillator & W-Si compact and high resolution Crystal calorimeters PbW & BGO BNL, Indiana University, Penn State Univ., UCLA, USTC, TAMU Pre-Shower W-Si LYSO pixel array with readout via X-Y WLS fibers readout via X-Y WLS fibers Univ. Tecnica Valparaiso “Cartesian PreShower” PID via Cerenkov DIRC and timing info Catholic Univ. of America, Old Dominion, South Carolina, JLab, GSI Catholic Univ. of America, Old Dominion, South Carolina, JLab, GSI RICH based on GEM readout e-PID: GEM based TRD eSTAR BNL, Indiana Univ., USTC, VECC, ANL BNL, Indiana Univ., USTC, VECC, ANL Tracking BNL, Florida Inst. Of Technology, Iowa State, LBNL, MIT, Stony Brook, Temple, Jlab, Virginia, Yale -Vertex: central and forward based on MAPS Central: TPC/HBD provides low mass, good momentum, dE/dx, eID good momentum, dE/dx, eID Fast Layer: -Megas or PImMS Fast Layer: -Megas or PImMS Forward: Planar GEM detectors
2
2e’t (Q 2 ) e L*L*L*L* x+ξ x-ξ H, H, E, E (x,ξ,t) ~ ~ J p p’ Inclusive Reactions in ep/eA: Physics: Structure Fcts.: F 2, F L Very good electron id find scattered lepton Momentum/energy and angular resolution of e’ critical scattered lepton kinematics Semi-inclusive Reactions in ep/eA: Physics: TMDs, Helicity PDFs flavor separation, dihadron-corr.,… Kaon asymmetries, cross sections Kaon asymmetries, cross sections Excellent particle ID ±,K ±,p ± separation over a wide range in full -coverage around * Excellent vertex resolution Charm, Bottom identification Exclusive Reactions in ep/eA: Physics: GPDs, proton/nucleus imaging, DVCS, excl. VM/PS prod. Exclusivity large rapidity coverage rapidity gap events ↘ reconstruction of all particles in event high resolution in t Roman pots
3
Scattered lepton: E e = 5 GeV -2 < < 1 E e = 30 GeV -4.5 < < -1 Produced Hadrons: increasing √s hadrons are boosted from forward rapidities to backward -3< <3 covers entire p t & z-region important for physics 3 Emerging Detector Concept: high acceptance -5 < < 5 central detector good PID ( ,K,p and lepton) and vertex resolution (< 5 m) tracking and calorimeter same coverage good momentum resolution, lepton PID low material density minimal multiple scattering and brems-strahlung Magnetic field extremely critical to get good tracking resolution in forward direction Integration of detector in IR design very forward electron and proton/neutron detection Roman Pots, ZDC, low e-tagger
4
4 To Roman Pots Upstream low Q 2 tagger ECAL W-Scintillator PID: -1< <1: DIRC or proximity focusing Aerogel-RICH 1<| |<3: RICH Lepton-ID: -3 < < 3: e/p 1<| |<3: in addition Hcal response & suppression via tracking 1<| |<3: in addition Hcal response & suppression via tracking | |>3: ECal+Hcal response & suppression via tracking -5< <5: Tracking (TPC+GEM+MAPS) DIRC/proximity RICH
5
5 10 mrad crossing angle and crab-crossing High gradient (200 T/m) large aperture Nb 3 Sn focusing magnets Arranged free-field electron pass through the hadron triplet magnets Integration with the detector: efficient separation and registration of low angle collision products Gentle bending of the electrons to avoid SR impact in the detector e p eRHIC - Geometry high-lumi IR with β*=5 cm, l*=4.5 m and 10 mrad crossing angle 20x250 20x250 Generated Quad aperture limited RP (at 20m) accepted
6
6 proton/neutron tag method o Measurement of t o Free of p-diss background o Higher M X range o to have high acceptance for Roman Pots / ZDC challenging Roman Pots / ZDC challenging IR design IR design Diffractive peak Large Rapidiy Gap method o X system and e’ measured o Proton dissociation background o High acceptance MYMYMYMY Q2Q2Q2Q2W How can we select events: two methods Need for roman pot spectrometer ANDZDC Need for Hcal in the forward region
7
7 leading protons are never in the main detector acceptance at EIC (stage 1 and 2) eRHIC detector acceptance e’ (Q 2 ) e L*L*L*L* x+ξ x-ξ H, H, E, E (x,ξ,t) ~ ~ p p’ t REQUIREMENTS Acceptance at large-|t| proper design of quadrupole magnets proper design of quadrupole magnets Acceptance for the whole solid angle High momentum resolution radiation hardness
8
5x100 GeV 20x250 GeV 8 Accepted in“Roman Pot” at 20m Quadrupoles acceptance 10s from the beam-pipe high ‐ |t| acceptance mainly limited by magnet aperture high ‐ |t| acceptance mainly limited by magnet aperture low ‐ |t| acceptance limited by beam envelop (~10σ) low ‐ |t| acceptance limited by beam envelop (~10σ) |t| ‐ resolution limited by |t| ‐ resolution limited by – beam angular divergence ~100μrad for small |t| – uncertainties in vertex (x,y,z) and transport – ~<5-10% resolution in t (follow RP at STAR) Simulation based on eRHIC Generated Quad aperture limited RP (at 20m) accepted 20x250
9
9 Results from GEMINI++ for 50 GeV Au +/-5mrad acceptance totally sufficient Results: With an aperture of ±3 mrad we are in good shape enough “detection” power for t > 0.025 GeV 2 enough “detection” power for t > 0.025 GeV 2 below t ~ 0.02 GeV 2 photon detection in very forward direction below t ~ 0.02 GeV 2 photon detection in very forward directionQuestion: For some physics needed rejection power for incoherent: ~10 4 For some physics needed rejection power for incoherent: ~10 4 Critical: ZDC efficiency
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.