Slide 2 Session Description This informative session will provide you with troubleshooting tools for Wonderware Application Server. Some of the topics which will be covered(but not limited to): Wonderware Tech Support Information Tool, Wonderware MSIChecker, Building a dialogistic Object Viewer, utilizing Object Viewer to find the problem, Troubleshooting engine\Historian issues & Deploy issues. Duration: 90 Mins
3
© 2012 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys are proprietary marks of Invensys or its subsidiaries. All third party trademarks and service marks are the proprietary marks of their respective owners. WW TSS-10 Application Server 2012: Advanced Troubleshooting Presenters: David Ujifusa Rich Liddell
4
Slide 4 Overview Wonderware Tech Support Info Tool Performance Monitor Mind Map App Server Tech Notes New Ideas for Troubleshooting Common Tools and Troubleshooting Demo Redundancy and Engine communications Deployment Demo Common Scripting Issues Galaxy Repository Queries and SQL Troubleshooting
5
Slide 5 How to attack install or version mismatch issues
6
Slide 6 Issue 1: Hotfix not installed correctly Symptom: Gets error message “From ZipFileInterop. Zip file interop - CreateFileW failed” importing View App into Galaxy SR 15316418 Tool Used: Wonderware Tech Support Info Tool Found that Hotfix 2177 was not installed properly
7
Slide 7 Issue 1: WW Tech Support Info Tool Customer presses Retrieve Wonderware Information, saves the result to an XML file and sends the XML file to Tech Support
8
Slide 8 Issue 1: WW Tech Support Info Tool Incorrect WWGalaxyRepositoryController.dll 3132.16.103.7 should be 3132.16.110.1
9
Slide 9 Issue 1: WW Tech Support Info Tool Demo WW Tech Support Info Tool What customer does How Tech Support analyzes
10
Slide 10 Issue 1: WW Tech Support Info Tool
11
Slide 11 Issue 2: NmxSvc Memory Leak Symptom: NMXSVC memory leaks 300 MB per day and climbs to 1.9 GB SR 15315695 Tool Used: Performance Monitor
12
Slide 12 Issue 2: NmxSvc Memory Leak
13
Slide 13 Issue 2: Performance Monitor Demo Performance Monitor Log File Configuration Analyzing the Log File
14
Slide 14 Issue 2: Performance Monitor Configuration Performance Monitor Configuration instructions Set up Performance Monitor to log all Processes and Processor. The general info for configuring a Performance Monitor Log File is found in the Help of Performance Monitor. Look for the article “creating counter logs” under “Performance Logs and Alerts.”. When creating the new Performance Log File press the Add Objects button. Select Process in the list of Performance objects and press the Add button. You will get a counter that looks something like \\davidu10\Process(*)\* Select Processor in the list of Performance objects and press the Add button. You will get a counter that looks something like \\davidu10\Processor(*)\* You can change the interval to something like every minute rather than every 15 seconds. Check that the Performance Log File size is growing to ensure that it is logging. When the test is finished send the.blg file to Wonderware Tech Support for analysis.
15
Slide 15 Issue 2: Performance Monitor Log File Analysis What Instances to look at? aaEngine* aaGR aaLogger sqlservr svchost* view*
16
Slide 16 Issue 2: Performance Monitor Log File Analysis Look at the Minimum and Maximum for these counters % Processor Time Handle Count Thread Count Private Bytes Virtual Bytes
17
Slide 17 Issue 2: Performance Monitor Log File Analysis Possible resource issue if one of these counters for a Process is increasing a lot or if the Maximum is high as follows: % Processor Time > 50 Handle Count > 1000 Private Bytes > 500 MB Thread Count > 100 Virtual Bytes > 500 MB
18
Slide 18 AppServer Troubleshooting Tech Notes Mindmap
19
Slide 19 AppServer Troubleshooting Tech Notes Mind Map
20
Slide 20 New Idea - AppServer Troubleshooting Symptom Mindmap or Word doc?
21
Slide 21 New Idea – Utility to check install files and DLL Registration
22
Slide 22 Trouble shooting - WTH
23
Slide 23 Where to look fast to find a problem
24
Slide 24 Common tools SMC Logger Log Monitor – Gift from Active factory Platform Manager Object Viewer SQL Profiler and SQL commands
25
Slide 25 Let’s dive into a case
26
Slide 26 Engines are losing objects over time Notes about the case: AppEngine_002 is having the problem right now 1)Engine deployed fine and all objects/attributes seemed fine 2)After a while View is no longer displaying some values stuck initializing 3)Object Viewer no longer shows the object under the engine 4) Redeploy states the object was never on this engine
27
Slide 27 Look at the SMC 1)Export SMC log so you are only looking a few days and not weeks 2)Filter out messages that are blocking the view and do not matter 3)If you know the engine name, filter for it to see what the engine has done lately 4)Search for words like terminate or aabootstrap starting, to see if the computer was rebooted or if the engine was terminated. 5)Filter only errors and warnings to narrow the search more
28
Slide 28 Open the exported Log file
29
Slide 29 Messages look like we are onto the problem ObjectSyncMgr AppEngine_002 MergeDeltaCheckpointsReq. *** Failed to update object 28 primitive 100 in object cache. Removing object from the cache... AppEngine_002: Deploy changes - [1 of 1] Failed to find object “NH3_DK_AD04" on the engine. Found MergeDeltaCheckpointsReq messages for AppEngine_001 too, but not for Engine_3 and Engine_4.
30
Slide 30 Engine Configurations are they different? 1)All Engines have Redundancy enabled 2) Engines 1 and 2 match but are different from 3 and 4. 3) Engines 3 and 4 match, and have not seen the problem 4) Difference is in the Redundancy settings Max. checkpoint deltas buffered = 10 Max alarm statechanges buffered = 10
31
Slide 31 What are the recommended settings?
32
Slide 32 Quote from Customer “I never knew how much I needed redundancy until I enabled redundancy” Not following the recommended settings for redundancy can make your system run unreliably.
33
Slide 33 Restarting Redundant engines
34
Slide 34 Expected Behavior for Redundant Engines 1)Active engine will only display in Platform manager 2) Task manager will show both engines running 3)If engine is stopped with Platform manager the other engine will start off scan and the stopped engine will remain at shutdown and will not be standby ready. A) Set the Active engine to Run on Scan B) Start the engine you stopped and it will clear from display
35
Slide 35 Creating Watch Windows
36
Slide 36 IDE has locked up and stopped responding.
37
Slide 37 What next restarting the IDE did not help. The aaGR process may need to be restarted on the GR node This process will effect all other IDE’s that are open, have all users close the IDE. Once this process is terminated the IDE will lose connection and will need to be restarted. We have a Power Shell utility to locate the user and IP for all nodes connected to the IDE called GetIDEUsers.ps1
38
Slide 38 Deployment
39
Slide 39 The IDE user deploys an object to a Platform Package Manager on the IDE node forwards this deployment action to the Package Server on the GR Package Server tells the PIM “Platform Installation Manager” to deploy the object’s runtime code modules and configuration files to the target Platform PIM on the GR node transfers the files to the remote PIM via the DCOMTransport Deployment: Mechanics
40
Slide 40 Quickest Way To Deploy Take advantage of multi threading during deploy Deploy all Platforms First at the same time Deploy All Engines at the same time Select Galaxy to deploy and set Currently deployed objects to “Skip”
41
Slide 41 Deployment issues: What can go wrong? DCOM NMX Local mode Version Binding order aaBootstrap not responding aaLogger hanging NIC setup – Auto detect Platforms still deployed but removed from GR
42
Slide 42 Tricks for keeping deployment moving Check Bind order #1 problem OSConfiguration utility – 3.1sp3p1 on 2008 sometimes requires the version from 2012 DCOM has probelms rerun Change network account If the IDE thinks the Platform is already deployed it might Need the Node removed form the registry on the remote node and GR.
43
Slide 43 Deployment issues: Undeployment Fails GR can not take the objects off scan so it fails NMX service is running in Local mode Engines are not responding Platform remover was used Can not communicate to the aabootstrap
44
Slide 44 Deployment issues: InTouch ‘Orange Icon’ What can make things go wrong? Maxuimum TCP connections achieved in non-server Machines Use Server OS on every node Use workarounds from Microsoft (search for ‘Remove Half-Open TCP Connection Limit’ in Google )
45
Slide 45 Deployment issues: Undeployment Fails What can I do? Use On Failure mark as Undeployed and try one of the following before undeploying Unplug the GR-Node from the Network Disable the NIC on the GR-Node or the Platform you are undeploying from. Only if RDP is not being used! In the registry on the GR [Hklm\Software\ArchestrA\Framework\Platform\PlatformN odes] give the platform you are trying to undeploy a bad IP address.
46
Slide 46 Analyzing Deployment Issues What occurs during deployment? GR Remote aaBootstrap How do I know anything is deploying? Task Manager Logflags
47
Slide 47 Demo Deployment
48
Slide 48 Engine communication issues I have done everything mentioned above. Why am I encountering an Engine communications failure?
49
Slide 49 Engine communication issues What can make things go wrong? External processes that consumes high CPU This can be caused i.e. by an unconfigured ArchestrA logger due to huge log file. Syncronous scripts for time consuming operations This can be caused by a SQL connect in a non- asyncronous script
50
Slide 50 Engine communication issues What can make things go wrong? External.NET modules that performs time consuming operations This can be caused by an external.NET dll that performs a time consuming calculation in the main process without using threads and semaphorization.
51
Slide 51 Scripting Considerations © Inve nsy s 200 9 Invensys proprietary & confidential S li d e 5151 Using the right script Debugging Logmessage() What is Async for Script Timeout/Error
52
Slide 52 Let the Engine / Object Relax While First Loading Use a while true script instead of a On true for large tasks (such as IO set reference). Delay with If Script.ExecutionCnt == 2 Invensys proprietary &
53
Slide 53 Use LogMessage() Why have needless Logmessages going to the logger unless required. Always block them in with an IF statement: If me.Debug then Logmessage(me.msg); Endif; ©Invensys proprietary &S
54
Slide 54 Async Scripts SQL scripts are a must Engine.AsynScriptMaxThread default size is 5 Engine.AsyncScriptsWaitingCnt use this for sizing AsynScriptMaxThread
55
Slide 55 Galaxy Repository Dive GR Useful Tables Gobject Gobject_Change_Log Lookup_operation View public_gobject_definition Platform Redundancy
56
Slide 56 How can I tell if someone deployed something? Gobject_Change_Log Objects affected Operation performed User Comment User Logged on
57
Slide 57 Return all operations for past 24 hours
58
Slide 58 Check to see if any engines have been deployed
59
Slide 59 Find checked-out objects
60
Slide 60 Useful SQL Find Checked out objects Check in objects Undeploy Galaxy Undeploy Platform Query Engines, Areas
61
Slide 61 How to write to Event Viewer from SQL Debugging a Stored procedure DECLARE @@MESSAGE varchar(255) select @@message = 'EventLogKey = ' + cast(@EventLogKey as nvarchar(32)) + ', EventTime = ' + cast(@EventTime as varchar(32)) + ', EventTagName = ' + @EventTagName EXEC xp_logevent 51000, @@MESSAGE, informational
62
Slide 62
63
Slide 63 Wrap up! Check out the Tech notes and Tools we suggested and practice trouble shooting Finding out what is different or changed often leads to the problem Understanding Deployment requires less colorful metaphors while troubleshooting Work on SQL skills and learn how to navigate the Galaxy