Published byGrace Adams Modified over 8 years ago
2
INVERTER PO-1500 SERIES 4
3
LOCATED IN PORT SIDE NOSE COMPARTMENT PROVIDES 115V AC SINGLE PHASE, 400HZ IN CASE OF FAILURE OF BOTH ALTERNATORS EQUIPMENT FAILS DUE TO FAN COVER DAMAGE FAILURE OF BEARING MALFUNCTIONING OF CENTRIFUGAL S/W RESISTORS OUT OF ADJUSTMENT FAILURE WILL CAUSE NON AVAILABILITY OF EMERGENCY BUS BAR (115V)
4
INVERTER PO-1500 SERIES 4
5
EQUIPMENT ELECTRO-MECHANICAL AND ROTARY IN NATURE. REQUIRED TO BE REPLACED WITH SOLID STATE STATIC VERSION, DESIGN CLEARANCE FROM CEMILAC THE REQUIREMENT FOR FIVE YEARS IS 150
6
- INPUT VOLTAGE – 27V DC±2.7V - INPUT CURRENT – 104 AMPS - OUTPUT VOLTAGE 115V AC±3.5V SINGLE PHASE, SINE WAVE - AC LOAD CURRENT – 13 AMPS OUTPUT FREQUENCY – 388 TO 420 HZ - OUTPUT POWER – 1500VA - EFFICIENCY – 48% MINIMUM - POWER FACTOR – 0.9 (INDUCTIVE) - OPERATING TEMPERATURE - ±60°C - ALTITUDE – 15,000 METER FOR CONTINUOUS OPERATION AT RATED LOAD, 1800 METER AT 75% LOAD - WEIGHT – 25.2 KG -SHOULD HAVE REMOTE ON/OFF AND OVERLOAD PROTECTION BY CIRCUIT BREAKER TECCHNICALTECCHNICAL SPECIFICATIONSSPECIFICATIONS