1 ACCESSIBLE BATHROOMS

2 GENERAL CRITERIA Use low flow, EPA's Watersense Program toilets Sensor control faucets to save water Lever handles on doors and faucets 32" clearance at door opening Non-absorbent flooring and walls to prevent spread of germs and allows easy cleaning Rounded base for ease of cleaning

3 WATER CLOSETS 17-19" AFF often referred to right height 16-18" to center of toilet from side wall Elongated bowl, hinged seat with open front

4 LAVATORIES Maximum of 34" AFF Counter depth 17 - 25" (max of 25") If using two sinks, they should be spaced 30" from centerline to centerline 27" clearance min. under the sink for kneespace 30 x 48 clear, unobstructed floor space in front of sink. 9" toe kick and 27" min knee clearance AFF. Hot water pipes must be covered and easily accessed

5 SINGLE-TOILET FACILITIES

6

7 MULTIPLE TOILET FACILITIES

8 TYPICAL ACCESSORIES

9 SIGNAGE