2 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting PharmSpec 3.0 Many of the functions have not changed –Procedural tests –Run Counter tests –IST tests –Procedure Builder –Historical reporting –Activity Log –Data Storage –Hardware settings
3
Bubble Detection Alarm 1) Clear description of alarm 2) Recommended actions 3) Potential cause and where to go for help Ships disabled as standard.
4
4 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting Invalid Configuration Alarm Current 9703 does not validate that the instrument configuration is not suitable for use New 9703 will: –Ensure the sampling probe, syringe, and flow rate setup are viable configurations The strength of the 9703 is its ability to manage a wide range of LPC application –We tested all possible mechanical configurations to ensure the instrument is not a contributor to bubble generation 1) Clear description of alarm 2) Recommended actions 3) Where to go for help
5
5 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting Concentration Limit Alarm Warns the user if the sensor detects excessive concentration in the sample A standard input during hardware setting 1) Clear description of alarm 2) Recommended actions 3) Where to go for help
6
6 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting Sensor Contamination Alarm Warns the user that the sensor is contaminated Probable causes: –Sensor window/cell is dirty –Void (air pocket) passed through the sensor –Significant over concentration of the sensor Recommendation: –Forward-flush the system multiple times with cleaning solution –For protein-users, we recommend Conrad 70 1) Clear description of alarm 2) Recommended actions 3) Where to go for help
7
7 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting PHA PHA enables –Troubleshooting –Secondary sizing validation –Diagnostic Dual channel PHA –Light Scattering –Light Extinction Changes: –Utilizing histogram –Added scatter
8
8 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting Batch Export Current version of PharmSpec 2.X only allows 1 test to be exported PharmSpec 3.0 will enable mass or selectable export functions to: –Word –Excel –Adobe –Text
9
9 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting Electronic Signature Improvements More strict interpretation of 21CFR Part 11 electronic signature process…. WITHOUT more manual inputs
10
10 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting Calibration Due Alarm Advanced awareness that your instrument is due for Calibration Configure your calibration due warning timeline or turn it off 1) Clear description of alarm 2) Recommended actions 3) Where to go for help
11
11 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting Probe Change Warning Sampling safety switch –Ensures the sampling probe does not crash (and bend or break) into the docking module. –Ensures the probe does crash and/or tip the sample container 1) Clear description of alarm 2) Recommended actions 3) Where to go for help
12
12 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting Configure Alarms and Alerts to Suit Turn them On! Turn them Off! Or do both! Factory default is off Ships disabled as standard.
13
13 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting Manage Multiple Alarms 1) Clear description of alarm 2) Recommended actions 3) Where to go for help
14
14 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting Customized Reporting
15
15 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting Customized Reporting
16
16 Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting Automation of Flush Routine Give your customers more walk away time Automate flushing/cleaning routines Step #1Place 1 ml - 1000 ml of Conrad 70, IPA, or other cleaning solution Step #2Push a button Step #3Walk away Step #4Return to a thoroughly cleaned instrument Estimated time savings: 20 - 30 minutes minimum
17
R&D: Partial Results Are Captured
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.