Measurements and calculations of the neutron spectrum in different irradiation channels of the TRIGA Mark II reactor, Slovenia R. Jaćimović 1, A. Trkov 2, M. Maučec 3 1 “Jožef Stefan” Institute, Ljubljana, Slovenia 2 IAEA, Vienna, Austria 3 HOLTEC International, Marlton, USA 1 st RCM of the IAEA CRP on Reference Database for NAA, Vienna, Austria October 2005
2
Introduction TRIGA Mark II reactor (250 kW) at the JSI from 1966. The k 0 -standardization method was introduced in 1987. TRIGA Mark II reactor (250 kW) –irradiation channels, –neutron spectral parameters, –neutron fluence gradients, –neutron self-shielding. Calibrated HPGe detector –absolutely calibrated point sources, –counting geometry.
3
Nuclear research reactor TRIGA Mark II (250 kW) - Short and long irradiation in the CC: th ~ 10·10 12 cm -2 s -1 - Short irradiation in the PT and in the FPTS (up-to 30 min.) th ~ 3.5·10 12 cm -2 s -1 - Long irradiation in the IC-40 (typically 20 hours) th ~ 1.1·10 12 cm -2 s -1
4
Horizontal section of the TRIGA Mark II reactor (core No. 176)
5
Relevant nuclear data used for determination of f and F. De Corte, A. Simonits, Atomic Data and Nuclear Data Tables, 85 (2003) 47-67.
6
Spectral parameters of the neutron fluence rate: f and
7
Experimental and MCNP results for thermal neutron fluence rate
8
Comparison of experimental results for reaction rate with these of Monte Carlo calculations in 11 carousel channels at the TRIGA reactor. Parameter f was obtained only by simulation
9
Temporal variation of the neutron fluence rate in the IC-40 channel F(t) = 1 + k·t
10
The power of the TRIGA Mark II reactor reading from the safety channel 27. and 28.1.2003
11
Temporal variation of the neutron fluence rate in the IC-40 channel 20. and 21.1.2003 TH2: at the mean of the pool water at 0.5 m depth TH1: at the entrance near the reactor wall at 1 m depth
12
Axial and radial gradients of the neutron fluence rate Fe wire = 0.4 mm Thermal neutron fluence rate: 58 Fe(n, ) 59 Fe Fast neutron fluence rate: 54 Fe(n,p) 54 Mn From the same spectrum !!!
13
Normalized specific activities of 59 Fe and 54 Mn vs. density for five matrices in the IC-40 and in the PT channels IC-40 PT IC-40PT
14
Specific activities and factors G th, F org and F inorg G th - not characteristic of nuclei, but depending of dimensions and composition of the sample G th,org = 1.01G th,inorg = 0.97 Cellulose Muscle H 2 O SiO 2
15
Axial and radial gradients of the thermal neutron fluence rate in different samples PTIC-40 -1.3%/cm 3.8%/cm 3.0%/cm 1.8%/cm
16
HPGe closed end coaxial detector (OR4) 40% relative efficiency at 1332.5 keV ( 60 Co) (dimensions are in mm)
17
Geometrical correction factor for absolute calibration for detector OR4 Detector OR4