Download presentation
Presentation is loading. Please wait.
Published byAudra Poppy Payne Modified over 9 years ago
1
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 1 B s Mixing at CDF Frontiers in Contemporary Physics Nashville, May 24 2005 Gavril Giurgiu – for CDF Collaboration Carnegie Mellon University
2
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 2 Introduction - Motivation: Constrain the CKM matrix elements - Within the Standard Model, B d/s mixing provides information on V td/s - Although m d is well measured (0.502 0.007ps -1 ) determination of V td is affected by 15% error
3
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 3 Unitarity Triangle - Unitarity of CKM matrix: - Knowledge of both B d and B s mixing frequencies would provide better constraints on one side of unitarity triangle: =1.15 0.05 from Lattice QCD
4
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 4 Current B s Status - B s mixing not observed yet - B s oscillates more than 30 times faster than B d experimental challenge - At 95% CL lower limit m s > 14.4 ps -1 with sensitivity of 17.8 ps -1
5
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 5 B Mixing Phenomenology - Neutral B system: - Mass eigenstates: - Oscillation frequency of B q mesons given by m q = M H -M L - Lifetime difference H L - Neglecting , mixing probability after time t is give by:
6
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 6 CDF Detector
7
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 7 CDF Detector – Schematic View Plug Calorimeter 1.3 < | | < 3.5 Central Tracker (COT) | | < 1.0 dE/dx for PID Time of Flight for K/p separation placed before 1.4 Tesla Solenoid Electromagnetic and Hadronic calorimeters Silicon Detector | | < 2.0 Muon Detectors | | < 1.0
8
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 8 Silicon Vertex Trigger (SVT) - Silicon Vertex Trigger implemented at Level 2 -Uses silicon detector information and beamline position to determine the track impact parameter -Good impact parameter resolution ~ 47 m: ~33 m beam size ~30 m intrinsic SVT resolution -Trigger on displaced track
9
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 9 Mixing Analysis Overview - Mixing analysis ingredients: - Signal reconstruction - Decay time - B flavor at decay - B flavor at production inferred through flavor tagging: - lepton tags - jet charge tags - Statistical significance of m s measurement: Tagging Signal Reconstruction Decay time resolution
10
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 10 SVT Triggers for B Physics Semileptonic (partially reconstructed) decays: B s lepton D s X - large number of events - decay time resolution degraded due to missing neutrino - triggered by 4 GeV lepton and displaced track with impact parameter |d 0 |>120 m and |d 0 |<1 mm Hadronic (fully reconstructed) decays: B s D s - smaller number of events - good decay time resolution - triggered by two displaced tracks with impact parameter |d 0 |> 120 m and |d0|<1 mm d0d0 d0d0 d0d0
11
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 11 Semileptonic B s Signals - Missing neutrino cannot see B s mass peak - Use D s mass peak and (lepton, D s ) charge correlation: l + D - - right sign combination l - D - - wrong sign combination - Decay modes: D s ( 4355 94 ) D s K*K ( 1750 83 ) D s 3 ( 1573 88 ) - Total of 7000 B s candidates but ~20% come from “Physics backgrounds”: B 0/+ D s D B s D s (D / D (s) lepton X) B s D s D (s)
12
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 12 Semileptonic B s Signals (cont) D s K*K ( 1750 83 )D s 3 ( 1573 88 )
13
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 13 Hadronic B s Signals - All final state particles reconstructed observe B s mass peak - Decay modes: D s ( 526 33 ) D s K*K ( 254 21 ) D s 3 ( 116 18 ) - Total of 900 B s candidates - Satellite peak: B s D s * (D s * D s X)
14
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 14 Hadronic B s Signals (cont) D s K*K ( 254 21 )D s 3 ( 116 18 )
15
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 15 Decay Time - Decay time: - In semileptonic modes missing neutrino is statistically corrected by: - Hadronic decays do not need correction - Decay time resolution: Hadronic: Semileptonic:
16
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 16 Decay Time Bias - Because: (1) In both hadronic and semileptonic decays the triggers require displaced tracks (2) B s events are selected based on decay distance cuts the B s decay time distribution is biased - Efficiency as function of decay time obtained from Monte Carlo:
17
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 17 Flavor Tagging - For B s mixing analysis CDF used 5 opposite side flavor taggers - Tag inferred from opposite side B in event: - muon and electron tag (semileptonic decay of opposite B) - three jet charge tag types: - displaced vertex - displaced tracks - high p T - Tagging power given by D 2 where is the tagging efficiency D = 1 – 2 P mistag is the tagging dilution P mistag – mistag probability - Large dilution (D) means high tagging power Trigger B meson
18
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 18 Flavor Tagging (cont) - Dependence of dilution on different quantities enhances tagging power - Dilution of lepton taggers is calculated as function of: - lepton likelihood (probability that lepton is real) - (transverse momentum of lepton w.r.t jet axis) - Dilution of jet charge tagger is calculated as function of - the jet charge: d i - displacement of track i w.r.t the primary vertex - Total D 2 1.6 % calculated on an inclusive lepton+SVT sample Electron tagMuon tag Jet charge tag
19
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 19 Tagger Calibration and Measurement of m d - Perform measurement of m d - Since we observe B 0 oscillations, we can also measure tag dilutions - Analyze hadronic and semileptonic decays of B 0 and B + : B 0 D + B + D 0 B 0 J/ K *0 B + J/ K + B 0 /+ D - l + X B 0 /+ D -* l + X B + /0 D 0 l + X - Event by event predicted dilution (D) - Fit the dilution calibration factor (S) for each of 5 tag types - Dilution calibration factors are used for the B s mixing analysis Event by event dilution Dilution Calibration Factor
20
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 20 m d Results - Hadronic: m d = (0.503±0.063±0.015) ps -1 - Dilution calibration factors: S(muon) = 0.83±0.10±0.03 S(electron) = 0.79±0.14±0.04 S(vertex) = 0.78±0.19±0.05 S(track) = 0.76±0.21±0.03 S(high p T ) = 1.35±0.26±0.02 - Total D 2 ~ 1.1% - Semileptonic: m d = (0.498±0.028±0.015) ps -1 - Dilution calibration factors: S(muon) = 0.93±0.04±0.03 S(electron) = 0.98±0.06±0.03 S(vertex) = 0.97±0.06±0.04 S(track) = 0.90±0.08±0.05 S(high p T ) = 1.08±0.09±0.09 - Total D 2 ~ 1.4% Muon Tags World average: m d = 0.502 0.007 ps -1
21
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 21 Lifetime Measurement - As a cross check of analysis framework measure B s lifetime - Lifetime fit projections in both hadronic and semileptonic modes - Semileptonic: c (B s ) = 443 10 (stat) xxx (syst) m - Hadronic: c (B s ) = 479 29 (stat) 5 (syst) m - Good agreement with PDG 2004: c (B s ) = 438 17 m
22
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 22 Amplitude Scan Method - Introduce Fourier coefficient A (amplitude) - Fix m at different test values and fit for A: (Moser et.al., NIMA 384 491) A 1 for true value of m A 0 away from true value - Test amplitude method on B 0 oscillations by scanning for m d in hadronic modes - points: A 1 - yellow band: A 1.645 - dotted line: 1.645 - Yellow band bellow 1 exclusion at 95% CL zoom in
23
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 23 B s Analysis - Performed “blind” analysis by randomizing the tag decision: tag = tag (-1) event number - Evaluate sensitivity and systematic uncertainties from “blind” analysis - Systematic errors evaluated using pseudo-experiments: - include all variables and distributions determined from data - fit the toy sample with different Likelihood configurations - use variations in Amplitude ( A) and statistical error ( A ) to derive the systematic error:
24
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 24 Semileptonic Amplitude Scan - Measurement is statistics dominated - Main systematic uncertainties from prompt background and from Physics background Sensitivity: 7.4 ps -1 Limit: m s > 7.7 ps -1
25
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 25 Hadronic Amplitude Scan - Measurement is statistics dominated - Main systematic errors come from tagger calibration Sensitivity: 0.4 ps -1 Limit: m s > 0.0 ps -1
26
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 26 Combined CDF result on m s - After combining semileptonic and hadronic modes: Sensitivity: 8.4 ps -1 Limit: m s > 7.9 ps -1 - With full B s momentum reconstruction, hadronic mode will dominate the measurement at high m s
27
Gavril Giurgiu, Carnegie Mellon, FCP Nashville 2005 27 Conclusions m s limits from CDF: Semileptonic: 7.4 ps -1 Hadronic: 0.0 ps -1 (will become important at high m s with more statistics) Combined limit: 7.9 ps -1, sensitivity: 8.4 ps -1 Results will substantially improve soon: - Same side Kaon tagger - Improve decay time resolution in hadronic modes - Add more data Updated analyses expected soon
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.