TOC & HPR Data Acquisition SM18 Raul Valera Teruel Rev 12015-05-26.

Similar presentations


Presentation on theme: "TOC & HPR Data Acquisition SM18 Raul Valera Teruel Rev 12015-05-26."— Presentation transcript:

1 TOC & HPR Data Acquisition SM18 Raul Valera Teruel Rev 12015-05-26

2 Parts of presentation Total Organic Content (TOC) system. – Ethernet connection & PLC installation. High Pressure Rinse (HPR) system. – Ethernet connection. – Access to laptop and PLC. – List of parameters. LabVIEW application. – Modbus. – OPC server.

3 TOC - Overview Control Room TOC

4 TOC – PLC & Ethernet Installation TN PLC

5 HPR - Overview Control Room TOC HPR

6 HPR – Ethernet Installation TN

7 HPR – Network Schema CERN TN

8 HPR – List of parameters Actual StatusActual Inner Purge TimeActual Set Dry RPM Cabinet Unload Door Lock Fail Auto Recovery RunningRotation Enabled Wand Lift Vertical Drive Not Ready Actual N2 Heater Temp Actual Outer Purge Time Actual Set Dry CyclesHeater Interlock FailWindows Closed Rotation Reverse Enabled Wand Lift Vertical MC Not Ready Actual FlowActual Dry TimeActual Lift StatusHeater OffAutomation Paused Rotation Table Home Running Recipe Not Found Actual ReistivityActual Set Top Of CavityActual Lift Percent Heater High Temperature Keyswitch OverrideTemp Control EnabledHigh Pressure Pump EMO Actual RPM Actual Set Bottom Of Cavity Cabinet Load Doors Open Incoming DIW Low Flow Wand Moving Incoming DIW Sample Enabled High Pressure Pump Fault Actual Rinse Cycles Actual Set Top Of Bellows Cabinet Unload Doors Open Incoming DIW High Flow Wand Overtavel Bypass Running Outgoing DIW Sample Enabled High Pressure Pump Stage 1 Fail Actual Dry Cycels Actual Set Bottom Of Bellows Cabinet Access Open Incoming DIW Low Resistivity Wand At Down PositionHPP EnabledHigh Pressure Pump Stage 2 Fail Actual Waste Water pH Actual Set Number Of Bellows Cabinet Computer Access Open Outgoing Waste Water Low pH Wand Ready Manual Mode Running High Pressure Pump Stage 3 Fail Actual Pump Speed Actual Set Nozzle Length Cabinet Plenum Full Outgoing Waste Water High pH Main Power Fail Valve Override Running High Pressure Pump Leak Detected Actual Pump StatusActual Set Rinse SpeedCabinet Exhaust Fail Rotation Table Home Fail Wand Lift Pause ButtonPower Present High Pressure Pump Compartment Door Open Actual TimeActual Set Rinse RPMCabinet CDA Fail Rotation Table Low RPM Wand Lift Vertical Negative Overtravel Alarm SilencedHigh Pressure Pump CDA Fail Actual Rinse TimeActual Set FrequencyCabinet N2 Fail Rotation Table High RPM Wand Lift Vertical Positive Overtravel Alarm Present Actual Set Dry Speed Actual Set Rinse Cylces Cabinet Load Door Lock Fail Power OffPLC Not CommunicatingReady To Start

9 LabVIEW application Main application for HPR and TOC systems. Modbus connection. *Possibility to create an OPC server. LabVIEW V3 V4 V5 TOC HPR LabVIEW TOC HPR OPC SERVER V3 V4 V5 LabVIEW

10 TOC & HPR Data Acquisition SM18 Raul Valera Teruel Pablo Fernandez Lopez Rev 12015-07-21

11 Parts of presentation Total Organic Carbon (TOC) system. – PLC Installation High Pressure Rinse (HPR) system. – PLC Setup LabVIEW application.

12 TOC – PLC Installation

13

14 Connected to the CERN TN. TOC – two channels readings (4 parameters each). – up to eight alarms can be programmed. Particle counter. – two channels readings. – Waiting for installation.

15 HPR Setup PLC not connected to the CERN network. Testing communication to the Siemens PLC. Outlet 2550 01 02 Switch LAPTOPPLC TNGPN

16 LabVIEW application

17 Thank you for your attention! If you have any question, please feel free to ask me!