Download presentation
Presentation is loading. Please wait.
Published byDominick Stephens Modified over 9 years ago
1
8114A Overview
2
8114A Overview 10-Feb-04 Page 2 8114A Overview 1) Specifications and Applications 2) Operational Overview 3) Block Diagram
3
8114A Overview 10-Feb-04 Page 3 8114A Sales Training Agenda 1) Specifications and Applications
4
8114A Overview 10-Feb-04 Page 4 8114A Key Specifications 1 Hz to 15 MHz Pulse Frequency up to 50.0 Vp-p (1 Amp) Amplitude into 50 Ohm Fixed Transitions of 5 Vpp (much better then <7 ns for ampl < 5 Vpp) Fixed Transitions of 10 Vpp (much better then <12 ns for ampl < 10 Vpp) Variable Pulse Width Optional Variable Pulse Baseline (± 25 V) Counted Burst Mode (up to 65536 pulses per burst) Graphic display, and Single-ended output Programmable by SCPI commands via GPIB
5
8114A Overview 10-Feb-04 Page 5 8114A Application Examples Power Semiconductor test Voltage margin test Flash memory test Diode, LED test Laser or IR Diode tests Radar distance test
6
8114A Overview 10-Feb-04 Page 6 8114A Training Agenda 2) Operational Overview
7
8114A Overview 10-Feb-04 Page 7 8114A Operating Concept I Graphic display gives access to all variable pulse parameters on eight parameter screens, selectable by softkeys and editable by knob or data entry panel Voltage or current source mode Settings can be stored either in 9 internal memory locations or on Memory Cards All parameters are remote programmable via GP-IB by SCPI commands
8
8114A Overview 10-Feb-04 Page 8 8114A Operating Concept II The six parameter screens: Trigger and Operating Mode screen: Output Screen:
9
8114A Overview 10-Feb-04 Page 9 8114A Operating Concept III The six parameter screens: Limits Screen: Memory Card Screen:
10
8114A Overview 10-Feb-04 Page 10 8114A Operating Concept IV The six parameter screens: Configuration Screen: Serial Number and SW Revision Screen : Press the [Help] button then the SERIAL# soft-button
11
8114A Overview 10-Feb-04 Page 11 8114A Standard Pulse Period Setting Period range is 66.7 ns to 999 ms represents frequency range from 1 Hz to 15 MHz Minimum resolution is 100 ps Accuracy is ±5 % ± 100 ps Trigger, Gate and External Width (max amplitude of 20 Vpp) modes
12
8114A Overview 10-Feb-04 Page 12 8114A Variable Delay Setting Delay range is 0.00 ns to (period - 4 ns), max 999 ms Set in reference to the trigger output Minimum resolution is 100 ps Accuracy is ±5 % ± 1 ns Fixed delay between Trigger output and main output is 42 ns typical
13
8114A Overview 10-Feb-04 Page 13 8114A Width/Duty Cycle Setting Width range is 10.0 ns to (period - 10.0 ns), max 150 ms Minimum resolution is 100 ps Accuracy ±5 % ± 500 ps Duty Cycle is subject to Width and Period, range is 0.1% to 100%. At maximum amplitude the duty cycle is limited to 15%.
14
8114A Overview 10-Feb-04 Page 14 8114A Double Pulse Setting Double Pulse range is 18.0 ns to (period - width - 10.0 ns), max 999 ms Minimum resolution is 100 ps Accuracy ±5 % ± 250 ps Minimum period is 133.4 ns (7.5 MHz) to achieve 15 MHz when double pulses are equidistant
15
8114A Overview 10-Feb-04 Page 15 8114A Transition Times Setting Fixed Transition Times of 5 Vpp Fixed Transition Times of 10 Vpp
16
8114A Overview 10-Feb-04 Page 16 8114A Programmable Output Levels Instrument is over-programmable to achieve the specified amplitude. Amplitude doubles into open circuits with 50 Ohm source impedance.
17
8114A Overview 10-Feb-04 Page 17 8114A Option 001, Variable Baseline Only for 50 source impedance Pulses within ±50 V level window Range: -25 V to +25 V Accuracy: ±1 % of setting ±100 mV ±0.5% of amplitude
18
8114A Overview 10-Feb-04 Page 18 8114A Training Agenda 3) Block Diagram
19
8114A Overview 10-Feb-04 Page 19 8114A Block Diagram VCO Clock Generator Up to 50 Vpp/1 A from 50 into 50 Optional Variable Baseline Trigger/Gate/Extern al Width Mode