Jennifer Thompson Western Michigan University Fermi National Accelerator Lab PST Program July 29, 2008 Mentors: Steve Hahn and JJ Schmidt
2
10 layers to the detector
3
2.5 MHz data acquisition rate Reduced to about 75 Hz through a series of three triggers Monitored 24 hours a day Ace responsible for checking Voltman
4
Data acquisition cards operate at specific voltages When voltage drifts too far, an alarm stops data collection Voltman provides real-time voltage values to the shift crew Web-page interface accesses Voltman database to view past values ◦ This is where most of our work took place
6
What is seen by the Ace Display for each section of detector Easy to identify location of fault
7
Constantly changing supplies and crates Lack of information Data retrieval not accurate Alarms aren’t preventative
8
Separate crate types Add links to web page Do we have them all? Are we actually monitoring what we need to?
9
Code readability (or serious lack thereof) ◦ Tidy program isn’t so tidy
10
Option allows user to plot a voltage from two power supplies at the same time Everything APPEARS to work properly… …but we were wrong. Plots are correct, data tables are not ◦ Duplicate tables
11
Should display all voltages of one crate Receive “No Valid Data” message for all voltages ◦ Know this isn’t true Run II upgrade to monitoring not compatible Still a work in progress
13
Gives expected versus actual voltage values Error details found here
14
Normal Alarm Severe Alarm – data taking stops Incorrect tolerance ranges on alert system Should have some warning so preventative measures can be taken before the point of data loss occurs Also a work in progress…
15
After most edits, something broke Majority of time spent trying to debug program Fix one problem, find two more… …or find a problem you just can’t fix.
16
Power supply list updated Web page updated Voltman updated Code reformatted Variable 1 & 2 corrected New errors corrected Still working “All” option ◦ New idea!