SQXF reaction cycle analysis Coils 001 and 101 N.Bourcey 07/11/2014.

Similar presentations


Presentation on theme: "SQXF reaction cycle analysis Coils 001 and 101 N.Bourcey 07/11/2014."— Presentation transcript:

1 SQXF reaction cycle analysis Coils 001 and 101 N.Bourcey 07/11/2014

2 Reminder on the furnace operation Slide F.Lackner (03/2012)

3 Too long to reach the dwell… decision to use SQXF-101 to optimize the cycle! Remarks: -No ventilation in the retort -Argon flow 2500-3000l/h in the retort

4 Instrumentation layout SQXF-101 tc19 tc20 tc14 Position of the thermocouple in block 5, 16 and 28.

5

6

7

8

9

10

11

12

13 Furnace program proposal to fit expected reaction cycle on coil MQXFS-102 StepTypeFrom temp [ °C] To temp [ °C] Rate [ °C/h] Duration [h]Comments 1Ramp2030050 2Dwell300 04.5 3Cool-down300215As fast as possible 4Dwell215 048+15To be adjusted online 5Ramp21550050 6Dwell500 01.5 7Cool-down500400As fast as possible 8Dwell400 48+3.5 9Ramp40066550 10Dwell665 050+12 11Cool-down66520