excom ® Remote I/O in Zone 1
2
excom ® excom ® One system for all requirements in Zone 1
3
excom ® Supply unit concept System connection Module overview Binary signal detection Analogue signal detection Housings Integration in Asset Management Systems Overall view of technological advantages Content
4
excom ® Supply unit concept Optimezed Power through the use of EEx-e input AC-supplying to the Backplane Design of the Backplane in EEx-m Galvanically isolated power supply of the modules with power restriction
5
excom ® Supply unit concept Power supply either 24 VDC or 115 / 230 VAC Fully redundancy Exchange in Zone 1 during operation 1 Supply unit is sufficient to supply a full equipped module rack
6
excom ® Supply unit concept 24 VDC 1 Supply unit 1 Supplyline 18-33 VDC
7
excom ® Supply unit concept 24 VDC 18-33 VDC 2 Supply unit 1 Supplyline
8
excom ® Supply unit concept 24 VDC 18-33 VDC 2 Supply unit 2 Supplyline 18-33 VDC
9
excom ® Supply unit concept 115 / 230VAC Same possibilities as with 24VDC Upgrade from an existing 24VDC- module rack possible
10
excom ® Supply unit concept mixed supply 115 / 230 VAC and 24 VDC 115 / 230 VAC 18-33 VDC
11
excom ® System connection Intrinsically safe Profibus DP Gateway Profibus DP-V1 Fully redundancy LED indication Hot swappable Configuration over Profibus HART ® -over-Profibus
12
excom ® System connection with copper cable DP SC12EX RS 485RS 485 iS Zone 1 max : 31 devices Control system
13
excom ® System connection with Fibre Optic Cable DP RS 485 max : 31 devices RS 485 iS OC11Ex/3G OC11Ex/2G LWL iS Zone 1 Control system
14
excom ® System connection with Fibre Optic Cable DP RS 485 Link cable Zone 1 LWL iS OC11Ex/3G 2 x OC11Ex/2G OC11Ex/2G RS 485 iS max : 31 devices Control system
15
excom ® System connection Redundancy possibilities DP SC12EX Zone 1 1 Control system 1 Profibus Master Control system
16
excom ® System connection Redundancy possibilities DP SC12EX DP SC12EX Zone 1 1 Control system 2 Profibus Master Control system
17
excom ® Control system B System connection Redundancy possibilities DP SC12EX DP Zone 1 2 Control systems each 1 Profibus Master Control system A
18
excom ® Module overview AIH40Ex AIH41Ex Other devices in preparation DM80Ex DF20Ex AO40Ex AOH40Ex TI40Ex Modules for: NAMUR-sensors and actuators mechanical contacts temperature sensors, thermocouplers analogue input-/outputs signals HART® -signal transmission DI40Ex DO40Ex AI40Ex AI41Ex
19
excom ® Binary signal detection 8 channels For connection either of NAMUR-sensors and actuators or mechanical contacts Input- and Output channels configurable Designed for connecting low power valves Configurable on/off delay in the range of 2...100 ms possible for each channel In-/output module – DM80Ex
20
excom ® Binary signal detection Input module – DI40Ex 4 channels Galvanic isolation between the channels For connection either of NAMUR sensors or mechanical contacts Configurable on/off delay in the range of 2...100 ms possible for each channel
21
excom ® Binary signal detection Output module – DO40Ex 4 channels Galvanic isolation between the channels automatic adjustment of power in the range of: 10..24 VDC Typical connected loads: 24 V/6 mA 18 V/25 mA 15 V/35 mA 12 V/45 mA
22
excom ® Binary signal detection Frequency module – DF20Ex 2 channels Counter or Frequency input Up to 4 kHz 2 main inputs with 3 control in-/outputs Control inputsfor: - direction detection - reset input - release input
23
excom ® Analogue signal detection Input module – AIH40Ex 4 channels Integrated HART ® Controller For connection of 2-wire- transducer 14 Bit-resolution 0..21 mA is reproduced as a figure between 0 and 21000 Up to 8 HART ® Variables in cyclic communication
24
excom ® Analogue signal detection Input module – AIH41Ex 4 channels Integrated HART ® Controller For connection of 4-wire- transducer 14 Bit-resolution 0..21 mA is reproduced as a figure between 0 and 21000 Up to 8 HART ® Variables in cyclic communication
25
excom ® Analogue signal detection Input module – AI40Ex 4 channels Galvanic isolation between the channels For cennection of 2- and 4- wire-transducers 14 Bit-resolution 0..21 mA is reproduced as a figure between 0 and 21000
26
excom ® Analogue signal detection Input module – AI41Ex 4 channels Galvanic isolation between the channels For connection of 4-wire- transducer Current input 0..21mA Voltage input 0..10,5 V 14 Bit-resolution 0..21 mA is reproduced as a figure between 0 and 21000 0..10,5 V is reproduced as a figure between 0 and 10500
27
excom ® Analogue signal detection Output module – AOH40Ex 4 channels Integrated HART ® Controller For connection of 0/4..20 mA actuators 12 Bit-resolution 0..21 mA is reproduced as a figure between 0 and 21000 Up to 8 HART ® Variables in cyclic communication
28
excom ® Analogue signal detection Output module – AO40Ex 4 channels Galvanic isolation between the channels For connection of 0/4..20 mA actuators 13 Bit-resolution 0..21 mA is reproduced as a figure between 0 and 21000 At connected HART ® devices the parameterization will be done direct on the device
29
excom ® Analogue signal detection Temperature module – TI40Ex 4 channels Galvanic isolation between the channels Resistant- or thermocoupler measurement 16 Bit-resolution 0,1 K per Digit from 0 Kelvin upwards Channelwise external cold junction compensation or internal for all
30
excom ® Housings Using in Zone 1 Stainless steel cabinet with window Mounting rail for module rack 2 Cu-shield bus Flange plate with cable glands Mounting of 1 x MT18 or 2 x MT9 IP65
31
excom ® Housings with system approval
32
excom ® Housings with system approval Temperature calculation with Excel Download from www.turck.com Selection of the used modules Automatic calculation of the power consumption Selection of the max. ambient temperature
33
excom ® Housings with system approval
34
excom ® Housings with system approval
35
excom ® Housings customerized solutions
36
excom ® Housings customerized solutions
37
excom ® Emerson AMS ® Suite FDT/DTM Technology Integration in Asset Management Systems
38
excom ® DTM’s HART ® Communication with FDT/DTM
39
excom ® HART ® Communication with FDT/DTM As with PACTware ® Download from PACTware ® (www.turck.com) Download of the DTMs from the sites of the manufactors Installation of PACTware ® and DTMs Build up a project: → CommDTM → excom ® DTM → Geräte DTMs Start!
40
excom ® HART ® Communication with FDT/DTM
41
excom ® Integration in Emerson AMS ® suite
42
excom ® Overall view of technological advantages Non-restrictive Power redundancy in Zone 1 Gateway redundancy Status Indication via LED Hot Swap for all components in Zone 1 Minor volume dimensions
43
excom ® Overall view of technological advantages One binary output module for quite all intrinsic safe valves One temperature module für all current temperature sensors and thermocpouplers Continuous HART ® Ccmmunication
44
excom ® Thank you very much for your kind attention. For any further questions, do not hesitate to contact us: TURCK TEAM PROCESS AUTOMATION pa@turck.com