Presentation is loading. Please wait.

Presentation is loading. Please wait.

E. Robutti. TOTEM 1. Measurement of the total pp cross-section. 2. Study of elastic proton scattering over a wide range in momentum transfer up to (–

Similar presentations


Presentation on theme: "E. Robutti. TOTEM 1. Measurement of the total pp cross-section. 2. Study of elastic proton scattering over a wide range in momentum transfer up to (–"— Presentation transcript:

1 E. Robutti

2

3 TOTEM 1. Measurement of the total pp cross-section. 2. Study of elastic proton scattering over a wide range in momentum transfer up to (– t)  10GeV 2 3. Measurement of the inelastic pp interaction in the forward region.

4 E. Robutti

5

6

7

8 Production status: support structure oBoth trusses ready in Genova –Now undergoing small upgrades to try and improve stiffness oAll chamber frames in production –5 th layer frame slightly modified in order to solve interference problem with beam pipe support chamber frames service frame

9 E. RobuttiTOTEM Collaboration Meeting, December 14, 20069 Production status: chamber components honeycomb panel cathode plane gas frame ground plane wire-holder oReady: –all components for type 1P, 5P (but 5P will be re-produced); –cathode planes, wire-holders, gas frames for type 1G, 5G, 5P new production; –PCB layout for all cathode planes and wire-holders

10 E. Robutti

11 TOTEM Collaboration Meeting, December 14, 200611 Chamber production at PNPI Measurement of cathode planarity

12 E. RobuttiTOTEM Collaboration Meeting, December 14, 200612 Chamber production at PNPI Wiring

13 E. Robutti

14 TOTEM Collaboration Meeting, December 14, 200614 Chamber production at PNPI Test set-up with temporary sealed chamber

15 E. RobuttiTOTEM Collaboration Meeting, December 14, 200615 CSC characterization at PNPI 1. Very low dark current (few nA) at “usual” HV values, raise starting from HV= (3.8 - 3.9) kV; 2. After irradiation with strong 137 Ce source ( about 15  A ), current returns to previous values  no self-sustained discharge ; 3. G ain uniformity within ±15% throughout whole chamber

16 E. Robutti CSC gas gain uniformity

17 E. RobuttiTOTEM Collaboration Meeting, December 14, 200617 Production database oAll results of quality controls and measurements for each chamber are stored in a database. Data will be made available through a web interface: example page (in the works) example page

18 E. RobuttiTOTEM Collaboration Meeting, December 14, 200618 Test beam set-up at CERN CSC #1 CSC #2 Anode read-out (AFEC) Scintillators (+PMT) Cathode read-out (CFEC) LV, PMT HV, cosmics trigger logic gas mixer

19 E. RobuttiTOTEM Collaboration Meeting, December 14, 200619 Dark current measurements at CERN oAt high voltage values both chambers could clearly “see” the beam

20 E. RobuttiTOTEM Collaboration Meeting, December 14, 200620 Production status: CSC components Tentative schedule for component readiness CSC typeWire-holderCathode panelGas frame 1Pready 1Gready31/1/07ready 2P31/1/0715/2 - 15/4/0731/1/07 2G31/1/0715/2 - 15/4/0731/1/07 3P31/1/0715/2 - 15/4/0731/1/07 3G31/1/0715/2 - 15/4/0731/1/07 4P31/1/0715/2 - 15/4/0731/1/07 4G31/1/0715/2 - 15/4/0731/1/07 5P (new)31/1/07 ready 5Gready31/1/07ready oAll material for 1/4 telescope: 15/3/07 oAll CSC for 1/4 telescope assembled: 30/4/07 (proposal under discussion)

21 E. RobuttiTOTEM Collaboration Meeting, December 14, 200621 Production status: read-out electronics 64-channel CFEC (CMS digitization) 128-channel CFEC (analog VFAT) VFAT simulator

22 E. Robutti

23

24

25

26

27 Эксперимент «Эпикур» (В.В.Сумачев) 1.Сделана часть трековой системы на базе ПК с шагом 1мм и апертурой 200*200мм. 2.ПК успешно прошли испытания на пучке ИТЭФ. Эксперимент «Эпикур» (В.В.Сумачев) 1.Сделана часть трековой системы на базе ПК с шагом 1мм и апертурой 200*200мм. 2.ПК успешно прошли испытания на пучке ИТЭФ.

28 E. Robutti Старение детекторов частиц в интенсивных радиационных полях Старение детекторов частиц в интенсивных радиационных полях

29 E. Robutti

30 Fig.2 Fig.1

31 E. Robutti


Download ppt "E. Robutti. TOTEM 1. Measurement of the total pp cross-section. 2. Study of elastic proton scattering over a wide range in momentum transfer up to (–"

Similar presentations


Ads by Google