Download presentation
Presentation is loading. Please wait.
Published byHorace Tate Modified over 9 years ago
1
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 1 LNE Center for Scientific and Industrial Metrology (CMSI) Thermal & Optical Division 29, avenue RogerHennequin 78197Trappes, France ( georges.bonnier@lne.fr ), R. Morice, J.C.Barbaras, N.Fleurence, V. LeSant, P.Ridoux, J.R.Filtz G. Bonnier Temperature Fixed Points and Thermal Effects
2
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 2 Within the frame of the EUROMET project 732, LNE have shared its activity in two parts : 1.LNE-INM (Saint-Denis) realizes new cells and take in consideration the effects of impurities 2.LNE-CMSI (Trappes is concerned with the thermal environment set up to realize the fixed point. The present paper deals uniquely with the point 2
3
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 3 Component of uncertainty linked with heat exchanges with the surrounding can be large
4
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 4 In association with a permanent heating process, a customary metal temperature fixed point is designed for : Maintaining an enclosure at a stable temperature Realizing uniform temperature enclosure Affecting a known temperature value
5
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 5 Schematic representation of melting and freezing process
6
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 6 Aluminium Freezing UME Cell
7
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 7 Aluminium Freezing UME Cell
8
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 8
9
9 Al Freeezing Point Plateau Results obtained by my Mai-Huong Vallin at LNE-INM Tx-Txbottom ; f= 0,08 Tx-Txbottom ; f= 0,14 Tx-Txbottom ; f= 0,25 Tx-Txbottom ; f= 0,40 Tx-Txbottom ; f= 0,55 Tx-Txbottom ; f= 0,63 Tx-Txbottom ; f= 0,70 Hydrostatic pressure effect
10
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 10 Indium cell Indium guard Thermometer Heat flux sensor Thermocouple Air pulsed furnace Heaters Where is located the liquid/solid interface ?
11
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 11 Temperature fixed point Design of a sealed cell
12
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 12 Percentage of remaining liquid 100% 80% 60% 50% 40% 30% 15% 0%
13
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 13
14
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 14 Percentage of liquid formed increases Melting process
15
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 15 Materialization of a temperature fixed point Freezing /melting and permanent heating Both freezing and melting are a function of time Effect of impurities Thermal effects Phase transition observed through calorimetric process The result is, in principle, independent of time
16
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 16 Schematic representation of a melt observed in a cryogenic sealed triple-point cell
17
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 17 Cryogenic sealed cell placed in adiabatic calorimeter
18
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 18 Hydrogen (13,8033 K) Deuterium (18,724 K) Neon (24,5561 K) Oxygen (54,3584 K) Nitrogen (63,151 K) Nitrogen (83, 8058 K) Carbon Dioxide (216, 592 K) mercury (234,3156 K) Water (273,16 K) Multicells
19
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 19 Realisation of the Silver point using a calorimetric method Simplified scheme : 1, Silver cell 2, thermal insulating material 3, positioning system 4, ceramic tube 5, radiation shields 6, heat pipe 7,cell-holding system 8, heater
20
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 20 Heater Principle of the adiabatic method used at LNE to realize ITS-90 metal fixed points
21
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 21
22
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 22 Temperature profile in the cell during heating time Solid Phase Liquid Phase Thermometer Temperature Distance
23
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 23 Aluminium freezing point, constant heat flux method
24
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 24 Aluminium freezing point. Calorimetric method
25
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 25 Indium cell Indium guard Thermometer Heat flux sensor Thermocouple Air pulsed furnace Heaters Design of the guard cell
26
Workshop « Towards more accurate fixed points » – St Denis – 23-24 November 2006 26 In summary: The principle of using the calorimetric method at any metal fixed point is established. The actual design has to be improved in order to get a final design. The final design must be easy to use. Using calorimetric method induces a better definition of a fixed point temperature.
Similar presentations
© 2025 SlidePlayer.com. Inc.