THEMIS Instrument FM2/FM3 PERFGM 1 Teleconference 8/30/2005 THEMIS Instrument FM2/3 Pre-Environmental Review Fluxgate Magnetometer (FGM) Dr Ellen Taylor University of California - Berkeley
2
THEMIS Instrument FM2/FM3 PERFGM 2 Teleconference 8/30/2005 Design Verification Design parameters same as FM1 FGE/FGS Calibration before delivery to UCB 8 test/calibration steps performed in Berlin, Braunschweig, Jeserigerhütten and Graz FGS Sensor Environmental Qualification FM2/FM3 (SN01/SN02) Vibration and TV test levels Parameters checked before and after tests FGE Electronics Environmental Qualification FM2/FM3 (SN01/SN02) Vibration and TV testing with IDPU Suite CPT done before and after tests No PFRs or modifications since FM1 PER FGM FM2/FM3 Overview
3
THEMIS Instrument FM2/FM3 PERFGM 3 Teleconference 8/30/2005 Design Verification All requirements in MRD verified Calibration Tests Digital functional test - check of board population, FPGA and current sources Analogue Adjustment of FGS and FGE - Test of excitation,input filter, phase adjustment, sensitivity and noise Parameters vs. Electronics Temperature - Test of offset, sensitivity, inrush current, phase in dependency on e-temp. Parameters vs. Sensor Temperature - Test of offset, sensitivity and noise in dependency on sensor temperature Test of non-linearity - Test of DAC non linearity and filter characteristics Earth field registration - Test of resolution and stability by comparison of F4 and F6 measuring Earth field variations Determination of sensor axis direction - Direction of magnetic axis determined with respect to mechanical ref. Frame Determination of scale value and orthogonality - Scale values and orthogonality check vs. sensor temp. in coil system FM2/FM3 Performance
4
THEMIS Instrument FM2/FM3 PERFGM 4 Teleconference 8/30/2005 Vibration Specs same as FM1 FM2/FM3 Vibration Test in Berlin: 6/28/05 to 7/2/04 Sine wave: up to 6.4g @ 50Hz Random noise: 11.7g RMS TV-cycle same as FM1 FM2/FM3 TV Test Performed in Graz: 7/01/04 to 7/03/04 Two cycles between -120°C and 90°C Parameter check (before, between and after tests) same as FM1 Resistance of all coils / Sensor output signals Coil constants and mechanical alignment of feedback coil system FM2/FM3 FGS Envir.
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.