Presentation is loading. Please wait.

Presentation is loading. Please wait.

Baseline Optimization Studies D. Reyna Argonne National Lab.

Similar presentations


Presentation on theme: "Baseline Optimization Studies D. Reyna Argonne National Lab."— Presentation transcript:

1 Baseline Optimization Studies D. Reyna Argonne National Lab

2 D. Reyna – Argonne National Lab2 1 May 2003 Some Basic Questions Does sensitivity to θ 13 survive under complete 3 flavor mixing? How can we best use all of the information in the energy spectrum? What are the optimal locations for 2 identical detectors? Bottom line: Can we achieve the desired sensitivity?

3 D. Reyna – Argonne National Lab3 1 May 2003 Independence of ∆m 2 solar atmospheric

4 D. Reyna – Argonne National Lab4 1 May 2003 Total Rate vs. Baseline E ν = 3.5 MeV Full Reactor Spectrum

5 D. Reyna – Argonne National Lab5 1 May 2003 Shape Comparison 1 km 100 m Make  2 Comparison Of Distributions Each bin normalized to total at that location Errors are statistical only

6 D. Reyna – Argonne National Lab6 1 May 2003  2 Comparisons Combined: Shape Test:  Minimizes Detector Specific Systematics  Loss of overall rate information  Assumes Identical Detectors  More Statistical Power

7 D. Reyna – Argonne National Lab7 1 May 2003 Optimizing 2 Locations  2 Identical Detectors  Fix 1 Detector Baseline  Sweep the Other 0.0015 0.002 0.0025 0.003 0.0035

8 D. Reyna – Argonne National Lab8 1 May 2003 Optimizing 2 Locations (cont’d) 100m 500m 1km 1.5km2km

9 D. Reyna – Argonne National Lab9 1 May 2003 Statistical Power of Combined  2 Test Combined (stat only) Combined (+ 1% sys) Shape Only (stat only) Shape Only (+ 1% sys)

10 D. Reyna – Argonne National Lab10 1 May 2003 Secondary Maxima? Combined (stat only) Combined (+ 1% sys) Shape Only (stat only) Shape Only (+ 1% sys)

11 D. Reyna – Argonne National Lab11 1 May 2003

12 D. Reyna – Argonne National Lab12 1 May 2003 90% Confidence Limits

13 D. Reyna – Argonne National Lab13 1 May 2003 Short and Long Solutions

14 D. Reyna – Argonne National Lab14 1 May 2003 Final Thoughts It is possible to get the desired sensitivity Optimal near detector location should be as close as possible A Detector should be at the first oscillation minimum (900 – 1400m) A farther location (~2.5km) yields almost as much statistical power  Could be effective if a very near detector is not possible  Possible 3 rd detector?


Download ppt "Baseline Optimization Studies D. Reyna Argonne National Lab."

Similar presentations


Ads by Google