Scissor Lift Accident Royal Arc Industrial Services 3 June 2014
2
Scissor lift in accident Representative sampleScissor lift in accident
3
Primary frame failure, both sides Hydraulic cylinder still extended Non-standard rails Sheet metal toe boards, tacked to rails and platform
4
Line cover not closed Electrical line repair with electrical tape Failure: tear in the box frame, both sides Painted over manufacturers data plate
5
Hydraulic cylinder attached on opposite side No visible fall restraint attachment points
6
Side view access right frame Bottom view access right frame Existing frame crack prior to failure New frame tear failure Existing frame crack prior to failure New frame tear failure
7
Existing frame crack prior to failure New frame tear failure Side view access left frame Painted over data plate
8
Lift controls Missing gate latch Unlabeled lift controls Missing control guards