Download presentation
Presentation is loading. Please wait.
Published byAlfred White Modified over 9 years ago
1
LT 3.121 EXIT Emergency Egress
2
LT 3.122 ENABLING OBJECTIVES DESCRIBE THE PURPOSE, FUNCTION, COMPONENT PARTS, OPERATING CHARACTERISTICS, SAFETY PRECAUTIONS & MAINTENANCE REQUIREMENTS FOR THE EEBD DESCRIBE THE ALLOWANCE & STOWAGE REQUIREMENTS FOR EEBD’S ABOARD SHIP DESCRIBE THE ALLOWANCE & STOWAGE REQUIREMENTS FOR SEEDS ABOARD SHIP
3
LT 3.123 DESCRIBE the purpose, function, component parts, operating characteristics, safety precautions & maintenance requirements for the Supplementary Emergency Egress Device (SEED) DESCRIBE the purpose & requirements for use of Photoluminescent Paint aboard ship ENABLING OBJECTIVES
4
LT 3.124 TEN COMMANDMENTS OF DAMAGE CONTROL ¶KEEP YOUR SHIP WATERTIGHT ·DO NOT VIOLATE MAT’L CONDITION ¸HAVE CONFIDENCE IN YOUR SHIP’S ABILITY TO WITHSTAND SEVERE DAMAGE ¹KNOW YOUR WAY AROUND -- EVEN IN THE DARK! ºKNOW HOW TO USE & MAINTAIN DAMAGE CONTROL EQUIPMENT »REPORT DAMAGE TO THE NEAREST DCRS ¼KEEP PERSONAL ARTICLES PROPERLY SECURED
5
LT 3.15 ½PRACTICE PERSONAL DAMAGE CONTROL. PROTECT YOURSELF SO YOU CAN PROTECT YOUR SHIP! ¾TAKE EVERY POSSIBLE STEP TO SAVE THE SHIP AS LONG AS A BIT OF HOPE REMAINS. ¿KEEP COOL; DON’T GIVE UP THE SHIP! TEN COMMANDMENTS OF DAMAGE CONTROL
6
LT 3.126
7
7 EMERGENCY EGRESS Personnel must perform Emergency Egress within 96 hours after arriving onboard and every 6 months thereafter Document on PQS Boards
8
LT 3.128 PHOTOLUMINESCENT PAINT Primary purpose: –Provide rapid Emergency Egress information –Identify locations of selected DC systems & Equipment Use paint or preformed signs 3-M Corporation sole provider for signs Ref: NSTM 079 Vol 2 pgs 18 - 23
9
LT 3.129 Emergency Escape Breathing Device (EEBD)
10
LT 3.1210 EEBD Description Self-contained Breathing Device
11
LT 3.1211 EEBD Description Self-contained Breathing Device Non-rechargeable, Non-repairable
12
LT 3.1212 EEBD Description Self-contained Breathing Device Non-rechargeable, Non-repairable Provides 15 minutes of Oxygen
13
LT 3.1213 EEBD Description Self-contained Breathing Device Non-rechargeable, Non-repairable Provides 15 minutes of Oxygen Provides flash and eye protection
14
LT 3.1214 EEBD Description Self-contained Breathing Device Non-rechargeable, Non-repairable Provides 15 minutes of Oxygen Provides some flash and eye protection Weighs 5 pounds
15
LT 3.1215 EEBD Description Self-contained Breathing Device Non-rechargeable, Non-repairable Provides 15 minutes of Oxygen Provides some flash and eye protection Weighs 5 pounds
16
LT 3.1216 Components Hood Nomex Shell Clear Viewing Window Elastic Neck Seal Support Harness
17
LT 3.1217 Nomex Shell Provides flash protection Similar material to shell of the FFE Includes no thermal barrier Components
18
LT 3.1218 Clear Viewing Window Permits vision flame resistant NOT Components
19
LT 3.1219 Elastic Neck Seal One size fits all No clothing or hair Components
20
LT 3.1220 Support Harness Automatically adjusts to fit Supports life support pack Components
21
LT 3.1221 Life Support Pack Oxygen Generator Carbon Dioxide Scrubber Relief Valve Components
22
LT 3.1222 Oxygen Generator Breakdown of Sodium Candle By-products are salt and heat Operates for 15 minutes Components
23
LT 3.1223 Carbon Dioxide Scrubber Reacts with Lithium Hydroxide By-products: ? Operates until reactant is exhausted Components
24
LT 3.1224 DONNING PROCEDURES OPEN CASE & REMOVE DEVICE OPEN VACUUM BAG PULL OUT ACTIVATING RING LISTEN FOR “HISSING” SOUND GRASP HOOD WITH THUMBS IN ELASTIC NECK BAND AND STRETCH OPEN PULL HOOD DOWN ON FOREHEAD
25
LT 3.1225 SAFETY PRECAUTIONS Stay away from flames for a minimum 15 Minutes (recommended) due to O2 Avoid neck seal leakage Unit is hot to touch Use for egress only not firefighting When activated, ensure no flames are present
26
LT 3.1226 AFLOAT SAFETY INFORMATION FOR MAY 1997 Area of discrepancy: Use, care, and maintenance of Personal Protective Equipment “EEBD donning & operation knowledge is low” “Photoluminescent paint markings were missing or worn”
27
LT 3.1227 Allowances Ship's Complement Embarked Personnel 150% 100%
28
LT 3.1228 Stowage Berthing Compartments100% (One EEBD for each sleeping surface)
29
LT 3.1229 Stowage Main Engineering Spaces 200% of maximum manning (Two EEBD's per each GQ watchstander)
30
LT 3.1230 Shelf Life United States Navy16 Years Manufacture date stamped on Humidity Indicator Card
31
LT 3.1231 Required Modification to humidity card 10 - 84 60 10 - 84 60 or
32
LT 3.1232 Required Modification to humidity card 10 - 84 60 Marks must be visible through inspection window
33
LT 3.1233 Stowage Bag Tear Strip Required Modification to Vacuum Bag 4 1/2" 1" TEAR NOTCH
34
LT 3.1234 Supplemental Emergency Egress Device (SEED)
35
LT 3.1235 SEED Overview NOT a replacement of the EEBD Used only in Engineering Spaces Provides 30 breaths of air (1-3 MIN.)
36
LT 3.1236 SINGLE STAGE REGULATOR ALWAYS PRESSURIZED SEED OUTFITTING = TO NUMBER OF PERSONNEL IN PROPULSION DIVISION READ PRESSURE ON PRESSURE GAGE - GREEN or RED STORED IN LOCKED CABINET SEED Overview
37
LT 3.1237 IMPROVED SEED HOLSTER Covered holsters Includes protective flap –Protects regulator –Allows viewing of pressure indicator –Secured with hook & pile fastener –Allows more rapid removal
38
LT 3.1238 Emergency Egress
39
LT 3.1239 KNOW YOUR WAY AROUND -- EVEN IN THE DARK! THE END