TE/MPE-TM 14.11.2013 GRZEGORZ SEWERYN THE UPGRADE OF TT SENSORS C-50 TO THE REDEL CONNECTOR 1.

Similar presentations


Presentation on theme: "TE/MPE-TM 14.11.2013 GRZEGORZ SEWERYN THE UPGRADE OF TT SENSORS C-50 TO THE REDEL CONNECTOR 1."— Presentation transcript:

1 TE/MPE-TM 14.11.2013 GRZEGORZ SEWERYN THE UPGRADE OF TT SENSORS C-50 TO THE REDEL CONNECTOR 1

2 TE/MPE-TM 14.11.2013 GRZEGORZ SEWERYN Overview Summary 2 1. What is the proximity equipment? 2. The need of DFB instrumentation upgrade 3. Decision on whether to exchange connectors in the tunnel or in the laboratory 4. Replacement of Cannon C-50 to REDEL connector 5. Number of Cannon C-50 connectors to be modified 6. Validation of the replacement: Continuity and HV test bench 7. Conclusion

3 TE/MPE-TM 14.11.2013 GRZEGORZ SEWERYN 1 What is the proximity equipment? 3 1. Connection box which routes the current lead temperature sensors and V-taps used for circuit protection 2. Drawing of the PE High current module

4 TE/MPE-TM 14.11.2013 GRZEGORZ SEWERYN  During ELQA tests of RB circuits, lot of HV breakdowns were observed!  The breakdown usually damaged the cryo conditioner card reading the temperature sensor.  TE/CRG claimed that the defect was mostly coming from the C50 connector which is not appropriate for HV  As a common agreement, it was decided to upgrade this C50 connector with a proper HV connector  Together with TE/CRG, it was decided to replace the Cannon C50 connector by the REDEL SLGH51 (Lemo) connector  After LS1, TE/CRG will consolidate their conditioner card, and the RB circuit will be tested at 2.1kV 4 2 The need of DFB instrumentation upgrade Cannon C50 Proximity Equipment

5 TE/MPE-TM 14.11.2013 GRZEGORZ SEWERYN 3 Do we upgrade it in the tunnel? 5 During a dedicated meeting among our section, we discussed the possibility of upgrading the PE in the tunnel or in the Lab: Advantages Disadvantages 1.Only one cable disconnection is needed (C50-1) 2.No need to dismount the box from the Frame 3.No risk of damaging the fragile cable segment 1.Poor illumination 2.Very bad access to the PE 3.Dust, noise… 4.More human resources needed

6 TE/MPE-TM 14.11.2013 GRZEGORZ SEWERYN 4 Replacement of Cannon to REDEL connector 6 Cannon connector (300V) Redel connector (3,2kV)

7 TE/MPE-TM 14.11.2013 GRZEGORZ SEWERYN 5 Number of Cannon C-50 connectors to be modified  16 connectors will be exchanged, all of them have been already delivered.  While mounting on the Proximity Equipment, a small metal plate, attached to the REDEL connector, will compensate the difference in size of the previous connector. 7 Fig 3. Redel connector with aluminium plate Fig 4. Redel connector modification, with aluminium plate in AutoCAD.

8 TE/MPE-TM 14.11.2013 GRZEGORZ SEWERYN 6 Validation, Continuity and HV test bench  A dedicated test bench was made for the Redel and Cannon C-50 connector tests.  The test bench consists:  Laptop with dedicated software  HV crate  Digital multimeter 8 Laptop with dedicated software HV crate Digital multimeter PE-Box

9 TE/MPE-TM 14.11.2013 GRZEGORZ SEWERYN 9 6 Validation, Continuity and HV test bench  A dedicated test procedure was written  After each test, a report is done and stored for future reference in ELQA dedicated folder in DFS

10 TE/MPE-TM 14.11.2013 GRZEGORZ SEWERYN 10  Up to date, three crates are fully upgraded and successfully tested.  There are 13 more crates that need to be upgraded  The estimated date for the completion of the project is February 2014  We do not foresee any delays 7 Conclusion