Download presentation
1
Aastra Communication Server Aastra 400
Hardware and build
2
Aastra 470 Communications Server
All-in-one Communication Solution including Call Manager, Media Gateway and Application Server in one single box 2HU metal housing with seven expansion slots for interface cards and Applications CPU card Mounting in 19 inch rack, cabinet or on desk Front-loadable interface cards (not hot swapable) Full front access for all cabling and maintenance, power from rear Display & control panel _AA002_en_03_a3_3805 Aastra 400 Hardware 2
3
Aastra 470 Hardware Portfolio
Basic System Application Card Terminal Interface Cards Trunk Interface Cards System Modules Basic System with CPU1 card CPU2 4FXS 1PRI DSP SM-DSPX1 8FXS 2PRI DSP SM-DSPX2 16FXS 4BRI IP media module EIP1-8 32FXS 8BRI Redundancy & Auxiliary options Installation Equipment IP media module EIP1-32 Auxiliary Power Supply unit APS2 Fan-out panel FOP 8DSI 4FXO 16DSI 8FXO Redundant Fan Unit RFU Cables 32DSI Basic system consisting incl. internal power supply, Call Manager CPU (CPU1), Cooling fan (1x), Plastic screw covers (one labelled), Empty slots closed with blind covers. Auxiliary Power Supply unit APS2 used in two cases: Redundancy mode: if internal PS fails, external APS2 takes over Boost mode: systems with large number of power consuming terminals. APS2 provides the extra power ~ 330W Redundant fan unit RFU: Optional backup fan runs in series with the primary fan. If one fan fails, the other still operates. Service staff can change fans before both have reached end of life. Fan speed control and fan failure supervision. System extension with Applications CPU2 card, interfaces cards, system modules CPU1 card hosts the Call Manager software providing business class telephony features. It performs call control, call-signaling, and media transcoding and conversion functions. FXO and high density FXS card foreseen with release 2.0 System cables allowing direct cabling Aastra 400->building installation. Fan-Out Panels (FOP) used for Aastra 470 systems with many corded terminals. High density interface cards > 8 interfaces can be patched using FOP’s. DSPX same as for Aastra 415/430, IP media modules same as for Aastra 5000 FXS: Foreign Exchange Station (analogue line) BRI: ISDN Basic Rate Interface FXO: Foreign Exchange Office (analogue trunk) PRI: ISDN Primary Rate Interface DSI: Digital Station Interface (digital line) _AA002_en_03_a3_3805 Aastra 400 Hardware
4
IP Media Module - EIP1 IP media modules connect the IP with the Non-IP world Two module types EIP1-8, EIP1-32 with different capacity Features: VoIP channels G.711, G.729A, echo tail length 128ms Fax over IP T.38 Voice encryption using SRTP DTMF Relay according to RFC2833 DTMF tone generation Line echo cancellation G.168 Fax tone detection _AA002_en_03_a3_3805 Aastra 400 Hardware 4
5
Mixed mode G.729 / Sec G.729 / FoIP-T.38
IP Media Modules - EIP1 EIP1 modules co-exist with embedded Standard Media Switch Both work independently and may use different Codec’s at a time EIP1 modules to be placed on CPU1 card (1), or PRI cards (1 or 2) Up to 5 such modules can be installed EIP1 media channels not licensed EIP1-SW is part of SW package 1.0. SW-update supported. The usage of the demand codec is dynamic. Max. Codec capacities (using Standard LEC). Mixed mode possible G.711/G.729/T.38 If all G.711 or Sec G.711 Mixed mode G.729 / Sec G.729 / FoIP-T.38 EIP1-8 32 8 EIP1-32 64 28 _AA002_en_03_a3_3805 Aastra 400 Hardware
6
SM-DSPX modules DSP modules placed on CPU1 card
Used for complex functions like coding/decoding audio signals Two module types; SM-DSPX1, SM-DSPX2 with 1 respectively 2 DSPs DSP functions (firmware) configurable with AMS or WebAdmin DECT, Voice Mail, GSM, VoIP, secure VoIP, FoIP VoIP G.711, G.729 with adaptive line echo cancelling G1.68 with configurable tail length of max. 128ms) Modules SM-DSP1 and SM-DSP2 (equipped with DSP TI-5507) are also supported. DECT, Voice Mail, GSM SM-DSPX1 and 2 equipped with DSP TI-5509A _AA002_en_03_a3_3805 Aastra 400 Hardware
7
IP Media Handling on Aastra 400
VoIP Media Gateway EIP DSPX ISDN SIP Digital IP Analogue IPT DECT
8
Basic Rate Interface - BRI cards
BRI cards connect the Aastra 470 with the public ISDN network or with ISDN- terminals & equipment. Two card types 4BRI, 8BRI with 4 or 8 interfaces respectively First 4 interfaces switchable by software from ISDN-T to ISDN-S; interfaces 5 – 8 fix (T). ISDN S-bus protocols: ETSI EXTERN S S-bus short or long (max.500 m) S bus point-to-point (max m) Cards comply with: TU I.430, TBR3 Switching S<->T by software (Admin tools) _AA002_en_03_a3_3805 Aastra 400 Hardware 8
9
Primary Rate Interface - PRI cards
PRI cards connect the Aastra 470 with the public ISDN network or are used to build up communication networks. Two card types with 1 or 2 interfaces B-channels licensing above 10 channels PRI cards with sockets to carry 1 or 2 IP media modules (EIP1). Cards comply with ETSI ETS /A2 ed.1 ETSI TBR 004/A1 ed.1 2PRI card can carry 2 EIP modules 1PRI card can carry 1 EIP modules 2PRI card carrying one IP media module _AA002_en_03_a3_3805 Aastra 400 Hardware 9
10
Digital Stations Interface - DSI cards
DSI cards connect the Aastra 470 with digital desktop phones and DECT system bases Aastra 5300 family, Office 10,25,35,45, SB4+,SB8 Three card types with 8,16 or 32 interfaces One or two terminals per interface Line length up to 1200 m Automatic line length surveillance (power measurement) DSI card equipped with 16 interfaces _AA002_en_03_a3_3805 Aastra 400 Hardware 10
11
Analogue Stations Interface - FXS cards
FXS cards connect the Aastra 470 with analogue phones and other analogue equipment. FXS = Foreign Exchange Station Three card types, 4, 8, 16 interfaces First two interfaces per card usable for long lines FXS card equipped with 16 interfaces _AA002_en_03_a3_3805 Aastra 400 Hardware
12
FXS cards FXS cards allowing to connect all kind of analogue equipment: Analogue phones, modems, answering machines, G3 fax etc.. 2-wire door equipment. Control functions with DTMF sequences. Line input for Music sources Control output to activate a relay, signal light…. (24V/300mW) Control input used to switch system from day to night (24V / >= 25mA) General bell _AA002_en_03_a3_3805 Aastra 400 Hardware
13
Aastra 415, Aastra 430 22.12.2011_AA002_en_03_a3_3805
Aastra 400 Hardware
14
Aastra 415 / 430 Hardware Portfolio
Main board MBA EIM EIM card holder SM 1 Connector for fan IC1 IC2 IC3 IC4 Interface internal Ethernet FXS AD2 WA1 WA2 WA3 WA4 _AA002_en_03_a3_3805 Aastra 400 Hardware
15
Aastra 415 / 430 Hardware Portfolio
Terminal Interface Cards Trunk Interface Cards System Modules Mounting Options Basic System Aastra 430 4xDSI EADP4 2xBRI TIC-2TS DSP SM-DSPX1 Cable Cover Kit 4xFXS ETAB4 4xBRI TIC-4TS DSP SM-DSPX2 Rack Mount Kit A430 Basic System Aastra 415 2xFXO TIC-2AB Rack Mount Kit A415 Special cards 4xFXO TIC-4AB Power Supply Door/Output/Inputs ODAB 1xPRI TIC-1PRI Portfolio includes Basic systems, cards, modules, mounting options and wiring adapters for the cards ODAB-card with Door Intercom Interface, Relay contacts, Sensor inputs FXS: Foreign Exchange Station (analogue line) FXO: Foreign Exchange Office (analogue trunk) DSI: Digital Station Interface (digital line) BRI: ISDN Basic Rate Interface PRI: ISDN Primary Rate Interface _AA002_en_03_a3_3805 Aastra 400 Hardware
16
Interface Cards Name Function Interface Cards per Aastra 415
Comment EADP4 User Interfaces AD2 4xAD2 2 4 AD2 interfaces only with A150/300. courtesy and voic embedded on mainboard ETAB4 User interfaces analogue 4xAB Interfaces to analogue terminals and devices TIC-4AB Analogue trunk interfaces 1 Pulse and DTMF dialling, tax pulse detection, CLI recognition TIC-2AB 2xAB TIC-2TS Basic Access Interfaces BA switchable T or S 2xT or S Both interfaces individually switchable T or S TIC-4TS Basic Access Interfaces BA partly switchable T or S 1xT fix and 3x T or S 1 port is fix T (not switchable) 3 ports individually switchable T or S TIC-1PRI Primary Rate Access 1xPRI 1 primary interface, 10 channels free , next 20 channels can be activated by licences ODAB Door Interface with relays or control inputs 1xdoor or 2xrelay + 2xinput With door: 1 relay contact or sensor input individually switchable _AA002_en_03_a3_3805 Aastra 400 Hardware