1 Innovations in ICP Sample Introduction
Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

2 Innovations in Sample Introduction
Summary of Discussion Low Flow Nebulizers Helix O’ring-free Spray Chambers New Internal Standard Kit Niagara Rapid Rinse Accessory Innovations in Sample Introduction Glass Expansion

3 Applications of Low-Flow Nebulizers
Limited sample volumes Volatile samples Expensive waste disposal ICP-MS-LC interface Low-Flow Nebulizers Glass Expansion

4 Range of Low-Flow Nebulizers
MicroMist- Concentric glass nebulizer 0.05 to 0.6 ml/min PolyCon- Concentric polyimide nebulizer 0.05 to 0.6ml/min OpalMist- Concentric PFA nebulizer 0.01 to 0.6ml/min Low-Flow Nebulizers Glass Expansion

5 Transport Efficiency vs. Uptake
UPTAKE RATE (ML/MIN) Indirect drain collection method Low-Flow Nebulizers Glass Expansion

6 Tertiary Flow Rate vs. Uptake
(ul/min) Low-Flow Nebulizers Glass Expansion

7 Corroboration of Tertiary Flow Rates
Uptake rate (ml/min) Indirect Method (mg/min) Direct Method* 0.03 15 14 0.11 23 21 Todoli, Hernandis, Canals, and Mermet, JAAS, 1999, 14, Using GE MicroMist nebulizer with U-tube absorption for measurement Low-Flow Nebulizers Glass Expansion

8 Primary Aerosol Size Distribution Comparison
Nebulizer Gas Flow Rate = 1.0 L/Min Solution Uptake Rate = Natural Aspiration D32 = 17.2 Conikal (2ml/min) 20 60 100 Normalized Count MicroMist (0.03ml/min) Normalized Volume 20 60 100 D32 = 7.1 Diameter (mm) 10 20 30 40 50 60 Diameter (mm) 10 20 30 40 50 60 Low-Flow Nebulizers Glass Expansion

9 Tertiary Aerosol Size Distribution Comparison
Nebulizer Gas Flow Rate = 1.0 L/Min Solution Uptake Rate = Natural Aspiration Baffled Cyclonic Spray Chamber Conikal (2ml/min) 20 60 100 D32 = 4.9 Diameter (mm) 20 60 100 D32 = 5.0 MicroMist (0.03ml/min) 10 40 30 50 Normalized Count Low-Flow Nebulizers Glass Expansion

10 New Micro-Flow OpalMist
All PFA construction Natural uptake rate of ml/min Ultra-high purity applications Ideal for micro samples down to 20 ul volume Low-Flow Nebulizers Glass Expansion

11 Cyclonic Spray Chambers Advances in Nebulizer Installation
1993 1984 1996 Helix O’ring free spray chamber Glass Expansion

12 Helix O'ring-Free Spray Chamber
Reduced carryover Faster washout Higher purity Can stand up to ketones and other solvents Helix O’ring free spray chamber Glass Expansion

13 New Internal Standard Kit Benefits of Internal Standardization
Compensate for physical interferences Viscosity Surface tension Compensate for some chemical interferences High salts Mass related effects (ICP-MS) Improve short term precision (simultaneous detectors) Decrease long-term drift Internal Standard Kit Glass Expansion

14 New Modular Internal Standard Kit
Glass Expansion

15 IS Tee with Built-in Mixing Chamber
Internal Standard Kit Glass Expansion

16 New Flared-End Pump Tubing
The final building block of a totally modular system Internal Standard Kit Glass Expansion

17 IS Schematic Peri Pump Sample IS Internal Standard Kit Glass Expansion

18 Niagara™ Rapid Rinse Accessory
Interfaces between ICP & Autosampler Reduces required rinse time Programmable delay time Less than 8 inches high Includes adj. height stand Rapid Rinse Accessory Glass Expansion

19 How Niagara Works Analysis Rinse Rapid Rinse Accessory Glass Expansion

20 Niagara Time Saving (30 sec rinse)
Standard System With Niagara Probe to sample 5 Uptake delay 15 Stabilization 10 Read Probe to rinse Rinse 30 Total (seconds) 80 55 = Rinse steps Rapid Rinse Accessory Glass Expansion

21 Summary MicroMist nebulizers Helix spray chambers
Efficient sample consumption Minimum waste generation Helix spray chambers Eliminate o’ring maintenance and contamination Reduce carryover Internal standard kit Improved accuracy without the work Easy & inexpensive modular replacement Niagara Rapid Rinse Accessory More samples per hour Faster sample turnaround time Rapid Rinse Accessory Glass Expansion