Download presentation
Presentation is loading. Please wait.
Published byEustace Charles Modified over 9 years ago
1
5.1.5.1 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. 1 Filter specifications: comparison of requirements for filter efficiency RBCP/SNS-Va Required Filtration Efficiency Improvement required depends on application, fuel contamination and life time 0 20 40 60 80 100 In-line Pump Distributor Pump Time-Controlled HP Injection Systems Filtration Efficiency 3-5 µm, % "Severe" conditions "Normal" conditions ISO/TR 13353:1994
2
5.1.5.1 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. 2 Filter specs: definition RBCP/SNS-Va Definition of Filtration Efficiency For BOSCH FIE filtration efficiency is defined according to the pre- standard ISO/TR 13353 :1994. Required filtration efficiency depends on application, expected fuel contamination and required life time (see following slides). For specific values see corresponding TCI In the meantime the standard ISO/TS 13353:2002 has become valid. Main difference to the pre-standard is the calibration procedure (ISO 11 171 instead ISO 4402). This requires an adaptation of the present values. The correlation is presently under preparation. The International Standard Organization is working on a new multi- pass method (ISO/DIS 19438) which should substitute ISO/TS 13353 in a few years
3
5.1.5.1 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. 3 Filtration efficiency RBCP/SNS-Va Definition of Filtration Efficiency 60 65 70 75 80 85 90 95 100 051015202530 Particle Size, µm Average Initial Efficiency, % 3 - 5 µm 5 - 10 µm 10 - 15 µm 15 - 20 µm20 - 30 µm> 30 µm Filtration efficiency has to be improved under consideration of application, fuel contamination and life time Flow Rate : 125 l/h Test Dust :ISO Fine Test Dust Test Method :ISO/TR 13353, Edition 1994-10-01
4
5.1.5.1 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. 4 Filter specification issue RBCP/SNS-Va TCD’s KM 45 110 004_en KM 45 110 005 and KM 45 110 007 describe Bosch requirements for fuel filter, water trap and allowed fuels for CR systems (CRS) Bosch offers Fuel filters for PC/LD-applications which fulfill DS- requirements for filtration in both normal and severe conditions Customers should be advised to use only the fuel filter with right specifications acc. to DS-requirements Protection of the injection system only possible by means of a suitable filter system
5
5.1.5.1 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. 5 Filter specifications normal conditions RBCP/SNS-Va
6
5.1.5.1 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. 6 Filter specifications severe conditions RBCP/SNS-Va
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.