Presentation is loading. Please wait.

Presentation is loading. Please wait.

Ericsson Tower Tube. Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24.

Similar presentations


Presentation on theme: "Ericsson Tower Tube. Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24."— Presentation transcript:

1 Ericsson Tower Tube

2 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-072 The challenge CREATE A NEW SITE THAT IS/HAS: Easy to place and build 1 Easy to run and maintain 2 Cost effective in every aspect 3 Low environmental impact 4

3 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-073 The solution: THE ERICSSON TOWER TUBE

4 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-074 IT IS A REVOLUTIONARY SITE BUILDING CONCEPT It’s a totally self contained site with room for all the equipment inside It leaves a very small footprint It’s architectural designed and has a character What is it?

5 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-075 The design and construction All equipment inside Indoor climate Small footprint approx. 5m diameter FULLY ENCAPSULATED SITE

6 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-076 Low feeder loss Positive impact on capacity, coverage and power consumption Prepared for site sharing RBS IN THE TOP The design and construction Antenna Array Radio base stations

7 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-077 The design and construction No need for active cooling

8 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-078 The equipment is installed in the base of the tower… … and is then lifted to the top with an elevator. RBS IN THE TOP The design and construction

9 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-079 THE RADOME PROTECTS THE ANTENNAS Protection from the weather, wind, dust and lightning 360° radio transparency The design and construction

10 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-0710 Concrete with post- tentioned steel wires Thin walls, approx. 70mm FLEXIBLE DESIGN The design and construction

11 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-0711 Modular design Built-in lightning protection in the construction MODULAR CONSTRUCTION The design and construction

12 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-0712 Superior design Low deployment cost Low cost to operate Low environmental impact Why the Ericsson Tower Tube?

13 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-0713 Superior design Awarded with Wall Street’s ”Technology Innovation Award” and nominated with Design-S Customized colors Accepted in the public environment Easier to find site locations Creates a landmark and an opportunity for branding Superior design

14 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-0714 Low deployment cost Small footprint and attractive design makes it easy to find locations 60-75% less footprint needed, compared to traditional sites Footprint of traditional site Footprint of the Ericsson Tower Tube

15 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-0715 Superior design Fences Shelter Grounding Cooling Feeders …all included in the Ericsson Tower Tube Low deployment cost

16 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-0716 Superior design Only indoor equipment is used Less feeder loss, capacity/coverage increase for network planning Macro flexibility Low deployment cost

17 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-0717 Low cost to operate Consumes low amounts of energy No need for long feeders nor active cooling, reduces power consumption by approx. 40% compared to traditional sites

18 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-0718 Superior design Requires a minimum of maintenance No need for security No need for gardening Low cost to operate

19 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-0719 Low environmental impact Saves energy Greatly reduced feeder loss and no need for active cooling A 40% CO 2 emission reduction could be obtained

20 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-0720 Superior design Saves resources The construction material has low environmental impact, uses 1/10th of steel compared to traditional sites CO 2 emissions related to material – production and transport – are at least 30% lower Low environmental impact

21 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-0721 Welcome to experience for yourself!

22 Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 22109 - FGB 101 472 Uen Rev DCommercial in confidence2008-11-0722


Download ppt "Ericsson Tower Tube. Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24."

Similar presentations


Ads by Google