Download presentation
1
Georgia Ground Water Resources Conference
AIR-SLUG LOW-PRESSURE PACKER SYSTEM TO FACILITATE CHARACTERIZATION OF FRACTURED ROCK Georgia Ground Water Resources Conference University of Georgia April 25, 2005
2
Head Measurement Hydraulic Test Sample Compressed Air Saprolite
Upper Packer STRADDLE PACKER Separation Pipe Lower Packer Head Measurement Hydraulic Test Sample
3
(LP) STRADDLE PACKER PIPE PLUG (Cherne Industries)
Pipe String Pipe Plug PIPE PLUG (Cherne Industries) Dia cm Length-45cm Inflation Pressure: 35psi Differential Pressure: 13psi (9m) ~$ per Pipe Plug SEPARATION PIPE ~1.4m PVC pipe 5/16” reinforcement rod Separation Pipe Pipe Plug
4
Air Slug Test h t Slug out Slug in Transducer and DAQ Regulator Valve
Compressed Air Valve h t Slug out Slug in Air Slug Test
5
FIELD APPLICATION (SC Botanical Gardens, Clemson Well Field)
Photo Log WELL-(LAR-4) FRX. LOCATION
6
FIELD DATA Transmissivity Example at 50.2m Slug Volume 5.5L
T = dwell2/t0.37 Similar to Hvorslev Method t0.37=~20sec dwell2=0.023m2 T=0.001m2/s
7
(LP) PACKER RESULTS 0.013 0.0016
8
(HP) STRADDLE PACKER ROCTEST Packers Length-150cm
Inflation Pressure: 800psi Differential Pressure: 200psi ~$ per packer
9
VERIFICATION
10
CONCLUSIONS The (HP) straddle packer system costs $ and requires a winch and several personnel to deploy, which can increase operational costs. The (LP) Straddle packer system costs $ and can be deployed without a winch using one or two personnel The (LP) packer system gives T results that are similar to the (HP) packer system T results. The effectiveness of the (LP) packer seal can be improved by stacking additional packers.
11
ACKNOWLEGEMENTS Murdoch, Larry (Advisor) Schweisinger, Todd (Student)
Elmore, Ryan (student) Hall, Richard (Student) Thanks To: National Science Foundation (NSF EAR )