© DIAMOND SA / 06-01 / 1 Accessories for modern Fiber Optic Installations Terminators, UGT (Optical transition adapters), Reflectors
2
© DIAMOND SA / 06-01 / 2 OTM OPTICAL TERMINATION MODULES
3
© DIAMOND SA / 06-01 / 3 Definition A Terminator is a fiber termination with the lowest possible back reflection A Terminator perform high Return Loss, good environmental stability and long working life A protection for open connections
4
© DIAMOND SA / 06-01 / 4 SMFAtt-FBreak Light-45dB-14dB Min. -45dB Total: Min. -104 dB The solution Based on doped attenuating fiber
5
© DIAMOND SA / 06-01 / 5 In real terms Mechanic and geometry of the standard connectors Pre-centered crimped ferrule without additional alignment Standard polishing process (PC or APC) Strongly attenuated fiber, minimum 15 dB/cm Simply cleaved fiber at the end of the “alberino”
6
© DIAMOND SA / 06-01 / 6 Products All “Alberino” connector as Terminators E-2000™, SC, FC, ST and F-3000™
7
© DIAMOND SA / 06-01 / 7 Typical RL values SM-PC: RL Min 45 dB SM-APC: RL Min 70 dB
8
© DIAMOND SA / 06-01 / 8 Applications Telecommunication distribution panels Measuring devices CATV Installations on open, temporarily unused channels
9
© DIAMOND SA / 06-01 / 9 OTA (UGT) OPTICAL TRANSITION ADAPTER
10
© DIAMOND SA / 06-01 / 10 Definition UGT are in line adapters for transition from PC to APC or from APC to PC technology An UGT perform high RL, good environmental stability and long working life. The ideal solution for an optimal, space-saving transition
11
© DIAMOND SA / 06-01 / 11 In real terms Mechanic and geometry from the standard in line attenuators (except E-2000™) non-attenuating standard fiber Standard polishing process (PC or APC)
12
© DIAMOND SA / 06-01 / 12 Products All connector system presenting attenuators E-2000™, SC, FC, DIN, ST Special solutions based on other connector standards upon request 0°/8° UGT
13
© DIAMOND SA / 06-01 / 13 Typical values IL max. 0.7 dB RL PC min 45 dB RL APC min 70 dB Repeatability of IL max. +/- 0.3 dB
14
© DIAMOND SA / 06-01 / 14 Applications Measuring devices As protection or transition element
15
© DIAMOND SA / 06-01 / 15 ORM OPTICAL REFLECTIVE MODULES
16
© DIAMOND SA / 06-01 / 16 Definition A Reflector is normally used as a fiber termination with the highest possible back reflection The reflection is performed by a perfect polished nickel alloy ferrule end face High reliability and repeatability
17
© DIAMOND SA / 06-01 / 17 In real terms Mechanic and geometry of the standard connectors Ferrule without hole - closed end face Standard polishing process (PC)
18
© DIAMOND SA / 06-01 / 18 Products All “Alberino” connector as Reflectors E-2000™, SC, FC, ST and F-3000™
19
© DIAMOND SA / 06-01 / 19 Typical values PC (0°) - ORM : RL < 1 dB (Standard nickel alloy insert.) Note:other ferrule types are available upon request
20
© DIAMOND SA / 06-01 / 20 Applications device manufacturer (reflectometers) device calibration