Download presentation
Presentation is loading. Please wait.
Published byMoris Warren Modified over 9 years ago
1
Use of Depth-Dependent Sampling to Determine Source Areas and Short- Circuit Pathways for Contaminants to Reach Public-Supply Wells, High Plains Aquifer, York, Nebraska Matthew Landon Brian Clark Allen Christensen 2006 National Water Quality Monitoring Council Meeting, San Jose, California May 9, 2006
2
Take-Home Messages Supply-well vulnerability can be strongly influenced by wellbores that cross confining units Sampling from different depths in supply wells, in addition to nearby monitoring wells, improves understanding of contaminant pathways to supply wells
3
Objective of Depth-Dependent Measurements Develop a refined understanding of where water and contaminants enter supply wells Depth-Dependent Sampling: –Provides a more detailed vertical profile than is possible with a monitoring well cluster –Is potentially useful for identifying short- circuit contamination pathways to the supply well
4
High Plains Aquifer TANC Study Area TANC Study Area
5
Monitoring network Sites with single wells screened near water table (8) Sites with nested wells (7) 1 km Regional ground-water flow
6
Geology and Well Construction – Supply Well Loess Unconfined sand & gravel Clayey till Confined fine sand Silty clay Confined fine sand Carlile Shale Supply Well screen
7
Tracer Pulse Method Conceptual Diagram Izbicki et al. (1999)
8
25% of flow from bottom half of screen Loess Unconfined sand & gravel Clayey till Confined fine sand Silty clay Confined fine sand Carlile Shale Supply Well screen Well-Bore Flow Profile 42.7 m 61.0 m Pump Intake 39.6 m Screen Cumulative percent of total flow Preliminary – Subject to Revision Velocity Measurements
9
Depth-Dependent Sampling Samples collected using a narrow- diameter pump lowered down an access tube that extends below the pump intake Loess Unconfined sand & gravel Clayey till Confined fine sand Silty clay Confined fine sand Carlile Shale Supply Well screen Depth- Dependent Samples
10
Depth Dependent VOCs Loess Unconfined sand & gravel Clayey till Confined fine sand Silty clay Confined fine sand Carlile Shale Supply Well screen Depth- Dependent Samples Similar results for: TCE, U, major ions, 18 O, D, N 2 Preliminary – Subject to Revision
11
Water 18 O and Cl Confined Supply well (includes depth- dependent) Urban confined mixed Ag unconfined Urban unconfined shallow Preliminary – Subject to Revision
12
Unconfined-Confined Mixing from D Loess Unconfined sand & gravel Clayey till Confined fine sand Silty clay Confined fine sand Carlile Shale Supply Well screen Depth- Dependent Samples Percent unconfined water Preliminary – Subject to Revision
13
Unconfined Mixing Fraction from D Confined Monitoring Wells At Supply Well Percent unconfined water Preliminary – Subject to Revision
14
Large vertical head gradients across confining layers Irrigation, commercial and old municipal wells are commonly screened in unconfined and confined sand layers Vertical Leakage Through Wellbores Confined Heads Unconfined Heads Preliminary – Subject to Revision
15
Contaminant Pathway Hypotheses Supply well (SW) leakage or drawdown induced leakage SW MW MW – Monitoring Well LW – Leaky Well (Multi-Layer) Areally uniform leakage through confining unit SW MW SW LW MW Wellbore leakage in multi-layer wells MW
16
Contaminant Pathway Hypotheses Supply well (SW) leakage or drawdown induced leakage SW MW MW – Monitoring Well LW – Leaky Well (Multi-Layer) Areally uniform leakage through confining unit SW MW SW LW MW Wellbore leakage in multi-layer wells MW Conceptual background confined concentration Conceptual unconfined concentration (increasing left to right) Fits measured chemistry data
17
Model Simulations Model simulations of ground-water age with MODFLOW-GWT (Ground Water Transport) and the MultiNode Well (MNW) package Please see talk by Brian Clark at 3:55 today for more details Simulations including wellbore leakage in multi-screen wells and known abandoned wells and test holes have the best match with observed age distribution
18
High Plains TANC Conceptual Model Denitrification Reductive Dechlorination Wellbore leakage Urban chemistry signature(s) Agricultural chemistry signature(s)
19
Conclusions Supply well vulnerability can be strongly influenced by wellbores that cross confining units Short-circuit pathways need to be considered in protecting ground-water supplies Sampling from different depths in supply wells, in addition to nearby monitoring wells, improves understanding of contaminant pathways to supply wells
20
Acknowlegements USGS National Water Quality Assessment Program Timothy Boyle Benjamin Dietsch Michael Turco City of York, Nebraska
21
Contact Information Matthew Landon U.S. Geological Survey 4165 Spruance Road, Suite 200 San Diego, CA 92101 Tele: 619-225-6109 Email: landon@usgs.gov TANC Website: http://oh.water.usgs.gov/TANCweb/NAWQATANC.htm
Similar presentations