Flat plate sensor location Installation options For more information: Rod Hyatt, (508) 542-9830 Rod.hyatt@htproducts.com ASKROD.com
2
Placing the sensor on flat plate collectors
3
Optimal sensor attachment Yes! Sensor is placed inside the collector, under the glass Not advised! The sensor does not penetrate the collector. * Will not work on drainback systems.
4
Sensor placement instructions Step 1: With a 15/64” sharp drill bit, carefully drill alongside the hot-out connection and insert the solar control sensor for better protected temperature sensing.
5
1.Drill sensor hole through grommet (illustrated on previous slide) 2. Sweat on plumbing connection 3. Lubricate drilled hole 4. Insert sensor for direct pipe contact Above: The sensor tip inserted inside the panel, placed against the header Left: The sensor, as seen through the glass of the collector Above: The sensor is lubricated and slipped inside predrilled hole
6
All done — neatly and efficiently