1 FoCal Status of Silicon Pad detector Array: Design and Tests 1.Review of results from last test beam 2.Plan for the test beam for 2015 11 March 2015.

Similar presentations


Presentation on theme: "1 FoCal Status of Silicon Pad detector Array: Design and Tests 1.Review of results from last test beam 2.Plan for the test beam for 2015 11 March 2015."— Presentation transcript:

1 1 FoCal Status of Silicon Pad detector Array: Design and Tests 1.Review of results from last test beam 2.Plan for the test beam for 2015 11 March 2015

2 Test and Characterization of a Prototype Silicon-Tungsten Electromagnetic Calorimeter VECC, Kolkata :: Sanjib Muhuri, Shuaib Ahmed Khan, Tapan K. Nayak, Rama Narayana Singaraju, Satyajit Jena BARC, Mumbai :: Sourav Mukhopadhay, Vinay B. Chandratre, Maneka Sukhwani and BEL, Bangalore Published in “Nuclear Instruments and Methods in Physics Research A 764(2014)24–29.

3 Silicon Pad 5x5 Arrays Each pad: 1cm 2 Laboratory set up: Layout of a 5*5 array of 1cm*1cm Silicon Detector 28 October 2014Sanjib Muhuri, IWAD 2014, VECC 3

4 Laboratory set up and results 28 October 2014Sanjib Muhuri, IWAD 2014, VECC 4 PMT1 PMT 2 Source- Sr90 Very thin scintillator to get 2 fold triggers Arrangement for the laboratory experiment

5 Development of the mini prototype Test Beam set up: Arrangement at T10 28 October 2014Sanjib Muhuri, IWAD 2014, VECC 5

6 Results From Test Beam Experiment: 28 October 2014Sanjib Muhuri, IWAD 2014, VECC 6 Responses from am minimum ionizing particle

7 Responses from electron ADC 28 October 2014Sanjib Muhuri, IWAD 2014, VECC 7

8 Actual Signal pions & electrons 4 GeV pions electrons Satisfactory Signal to noise separation 28 October 2014Sanjib Muhuri, IWAD 2014, VECC 8

9 Longitudinal Shower Profile Reconstruction 28 October 2014Sanjib Muhuri, IWAD 2014, VECC 9

10 To check The Linearity of the detector… 28 October 2014Sanjib Muhuri, IWAD 2014, VECC 10 Shows good linear behavior with respect to the simulation

11 36 element Silicon Pad detector 1 sq cm silicon pads in 6×6 array.320 microns. common n. Bias applied negative to p type pads. Signals from p type pads through capacitors. Bonding diagram for pads.

12 Detector assembled on the PCB Bias resistors and coupling capacitors 40 pin connector for signals Wire bonds from pads Guard ring position one corner Before wrapping in a black sheet and Al foil Guard rings left floating

13 PMT1 PMT2 Detector FEE Board Translator Board Testing 2 fold from PMTs is trigger to DAQ. Same backplane PCB made for 25 elements. MANAS/ANUSANSKAR readout. 31 1 X 15 23 20 ? 29 5 11 X X 28 0 18 26 25 X 7 ? 22 21 2730 19 24 17 16 14 13 12 10 9 8 4 ? Numbers inside the squares are DAQ channels. 4 channels left out(marked as X), since we can only read 32. 3 channels bad on FEE board. Fig needs minor corrections. Test SetupMapping of Pads to DAQ Channels for one position Backplane PCB

14 RMS study with Bias  4 detector pcbs can be connected to one backplane PCB. Read by 2 FEE boards.  2 detector PCBs are read by one FEE(64 channels).  Connected only detector PCB to backplane PCB.  So only 32 channels (0 to 31) show higher RMS compared to other 32(32 to 63)  RMs is high at bias 0v and decreases with increasing bias voltage. Stabilizes >45V.  Few times rms has gone bad for some channels. Mean adc values have gone down to zero. See next 2 slides @0V @30V@45V @60V @70V@80V

15 @0V @30V @45V @60V On 21.08.13 Pedestal Study-1 Mean ADC values for some channels have gone down- channels above colored circles. Suspect humidity- The silicon gels have gone pale.

16 @0V@30V @45V @65V 0n22.0813 Pedestal Study-2 Mean ADC values for all channels have normal values. None close to zero Kept the detector inside desiccators with new silicon gels over night. Humidity in the lab also more due to rains..

17 First signals

18 Status and plans for the test beam (PS and SPS) A new PCB for Silicon pad detectors is being made Pad detectors to be mounted on the PCB Prepare the readout with MANAS and ANU chips Prepare the tower Present tower design is 4 Si-pad detectors in each plane Tests can be done with single Si-pad detector in each plane or with 4 Si-pad detectors in each plane We have 25 tungsten plates (10 cm x 10 cm) We can organize properly to gain maximum information during the tests Provision for inserting MAPS detector in between ….

19 Arrangement for the Test Beam – Oct 2015 4 Pad detectors: each 6x6 array Each pad: 1cm x 1cm 4 tungsten plates: each 10cm x 10 cm