Th, Pu & U Separation Using TEVA and UTEVA Resin
Eichrom Workshop at RRMC 12 November, 2002 Knoxville, TN
2
Objective To develop a quick method for the separation of
Th, Pu and U in water samples
5
Tracers U232 tracer cleanup required to remove daughter Th228
Followed David Sill (NAREL)’s BaSO4 procedure Pu242 and Th229 used for plutonium and thorium Pu236 better choice if Np measurement is required
6
Sample Preparation 1 liter aliquots of acidified water samples were spiked with Th229, Pu242 and U232 tracers Samples were heated to near boiling for 2 hours A Ca3(PO4)2 precipitation was performed Decant supernatant, centrifuge and collect the precipitate
7
Load Solution Dissolve precipitate in 3M HNO3/1M Al(NO3)3 solution
Add ferrous sulfamate and NaNO2 Load on TEVA and UTEVA Resin cartridge in tandem
8
Proposed Procedure 1) Attach TEVA resin and UTEVA resin cartridges in tandem 2) Load 10 ml of 3M HNO3/1M Al(N03)3. with 2 mL of 0.6M Ferrous sulfamate followed with 1 ml of 3M NaNO2 3) Rinse sample beaker with 5 mL of 3M HNO3 4) Rinse cartridge with 5 mL of 3M HNO3 5) Separate TEVA and UTEVA cartridges
9
Proposed Procedure continued
TEVA cartridge 1) Rinse with 30 ml of 3M HNO3 2) Elute Th with 20 ml of 9M HCl and 5 ml of 6M HCl 3) Elute Pu with 20 ml of 0.02M TiCl3/0.05M HCl/0.05M HF (Np eluted in this fraction)
10
Proposed Procedure continued
UTEVA Cartridge 1) Rinse with 5 ml of 9M HCl 2) Elute U with 15 ml of 1M HCl
11
Direct Spike Results (Proposed Procedure)
12
U fraction contaminated with Pu
13
Improvements Needed Possible Pu valence adjustment for better recoveries U recoveries need to be higher Better decontamination for U fraction
14
Possible Solutions for Improvements
1) Use 2 ml of ferrous sulfamate ml of NaNO2 2) Use 1 ml of ferrous sulfamate + 1 ml of NaNO2 3) Increase U and Pu strip volumes 4) Add oxalic acid rinse on UTEVA
15
Direct Spike Results (2 ml of Ferrous+0.5ml of NaNO2 )
* With 25 ml of Pu strip volume **With 20 ml of U strip volume & oxalic acid rinse
16
Direct Spike Results (1 ml of Ferrous + 1ml of NaNO2)
*With 25 ml of Pu strip volume **With 20 ml of U strip volume & oxalic acid rinse
17
Revised Procedure 1) Load sample on TEVA resin and UTEVA resin cartridges in tandem with 10 ml of 3M HNO3/1M Al(N03)3. with 1.0 mL of 0.6M ferrous sulfamate and 1 ml of 3M NaNO2 2) Rinse sample beaker with 5 mL of 3M HNO3 3) Rinse cartridge with 5 mL of 3M HNO3 4) Separate TEVA and UTEVA cartridges
18
ACW13 continued TEVA cartridge 1) Rinse with 5 ml of 3M HNO3
3) Elute Th with 20 ml of 9M HCl and 5 ml of 6M HCl 4) Elute Pu with 25 ml of 0.02M TiCl3/0.05M HCl/0.05M HF (Np will be present in this fraction)
19
Revised ACW13 continued UTEVA Cartridge 1) Rinse with 5 ml of 3M HNO3
2) Rinse with 5 ml of 9M HCl 3) Rinse with 20 ml of 5M HCl/0.05M oxalic acid 4) Elute U with 20 ml of 1M HCl
20
Decontamination Test ~100 pCi of Am, Np, Th, Pu and U were added to the load solution Solution was processed following ACW13
21
Decontamination Factors
22
DI Water
23
Th229 Spectrum
24
U232 Spectrum
25
Pu242 Spectrum
26
Tap Water
27
Summary Benefits Drawbacks
A quick method with consistent, reproducible recoveries Rugged enough to provide good decontamination from other actinides Drawbacks Th228 cleanup required Pu236 tracer required if Np237 measured