1
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it M3R3-M5R3-M5R4 FEE status
2
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 2 Overview FEE – from ASDQ to CARDIAC ASDQ++ CARDIAC I2C induced signals HV induced noise HV noise coupling LV distribution Regulator Vout spread & LV distribution bars Vdrop CARDIAC threshold scan M3R3 – M5R3 – M5R4 Grounding Detector grounding scheme Conclusions
3
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 3 ASDQ++ A brief history (I) Nightmare first two chambers prototypes test fee instability cable layout/orientation sensitivity ASDQ++ PCB rel. 2 small improvement on the instability side still problems with cabling Buffer board & FC connections fully stable fee behavior no dependency on cable layout - Some capacitors for supply voltage decoupling - inner layers for GND/V+/V-
4
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 4 ASDQ++ A brief history (II) Programmable current sink ASDQ output stage standard current set : 3 mA (300 mV/100 ) current set for driver board : 1 mA (300 mV/300 ) R=300 SPB ASDQ++ Ground connection Faraday cage HV 1 M 680 nF Faraday Cage sensitive path Cathode pads readout LVDS
5
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 5 ASDQ++ A brief history (III) Pads X-talk charge injection in pads belonging to the same pad wire charge injection in contiguous pad wires HV Signal on this wire pad Signal injection charge injection in pads belonging to the same pad wire poor ground connection (capacitor-GND) charge injection in contiguous pad wires nose ground not enough a resistor in the grounding path mitigates the problem and help with HV & pickup noise Z GND < Z Wire Pads HV nose
6
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 6 The IB System architecture The IB and the TB boards HV Signal on this wire pad Signal injection Z GND << Z Wire Pads HV nose 22 In the last T11 TB 4 CARIOCA (NOT CARDIAC !!!) boards were installed in one of our M3R3 chamber. We took some data @ V th 6/7 fC
7
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 7 CARDIAC I2C induced signals (I) I2C A B C D E F Termination
8
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 8 CARDIAC I2C induced signals (II) Read Scaler Read all registers M3R3 CARDIAC : A – B – C – D [all channels] M3R3 CARDIAC : F [1° (?) channel – other channels ok] Read all registers Read Scaler NB : 5 pulses are generated by the readout procedure (?!) ask to Valerio CASINO ? I2C CARDIAC out I2C CARDIAC out I2C CARDIAC out
9
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 9 CARDIAC I2C induced signals (III) I2C A B C D E F Termination All boards/all channels OK Problems in the PCB due to high frequency signal components CARDIAC F – 1° channel
10
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 10 CARDIAC I2C induced signals (IV) Termination I2C A B C D E F No ch1 problem with M5R3 chamber ??!! M3R3 – M5R3 difference : C pad value M5R3 C pad I2C line Z1Z1 Z2Z2 I1I1 I2I2 CARIOCA C parasitic What are we going to have with smaller C pad and shorter interconnection cables ?
11
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 11 HV induced noise Noise coupling Continuous cathode Wire Cathodes HV distribution line = antenna I noise filter HV before distribution line 6 cm V < 5 V C = 2.2 nF
12
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 12 LV distribution Regulator output voltage spread I load =1.5A 60 mm LV distribution bars - PCB dimension for region R4 800 mm R=0.45 m/□ R = (800/30)*0.45 m Voltage drop ~ 20mV (< 1% Vcc) GND VCC
13
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 13 CARDIAC threshold scan M3R3 – M5R3 – M5R4 M3R3 100 Hz @ 4.4 fC (working threshold = 5 fC) M5R3 100 Hz @ 6.4 fC (working threshold = 5 fC) M5R4 100 Hz @ 8.2 fC (working threshold = 10 fC) HV ON
14
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 14 Grounding Detector grounding scheme No current through the reference GND Reference GND = Safety GND 3 A fuses on the LV distribution system 1 mA max current on the HV lines Low step up current in case of failure No current through the reference GND Reference GND = Safety GND 3 A fuses on the LV distribution system 1 mA max current on the HV lines Low step up current in case of failure system reference ground safety ground
15
CARDIAC meeting – 30 Sept 05 giulietto.felici@lnf.infn.it 15 System qualification Skew measurements M4(M5)R3 To verify front-end behavior threshold scan should be executed WITHOUT HV ON (HV is a source of external noise and can be filtered out), anyway FEE work fine with the 3 instrumented chambers No instability due to cable layout or external source has been detected HV filters are OK with the HV PS we have used in our test, but that PS is not the final one ! LV boards and LV distribution are OK (~10 mV drop for M3R3 regions and ~20 mV for M4R4 regions) The detector grounding scheme has already been (successfully) reviewed The 3 instrumented chambers work fine (NB : M5R3 is not instrumented with the final FC) I2C access can trigger CARDIAC output spurious pulses ONLY during CARDIAC access According to our tests CARDIAC work fine when used to instrument M3R3, M5R3 and M5R4 chambers