Download presentation
1
Laboratory Equipment and its Usage
2
Safety Glasses and goggles: Use to protect your eyes
Safety Glasses and goggles: Use to protect your eyes. MUST be worn at ALL times in the lab ONLY taken off when instructed!!!!!!!
3
Electronic Balance: Used to measure the mass of a solid. NOTE: 1
Electronic Balance: Used to measure the mass of a solid. NOTE: 1. NEVER mass a solid chemical directly on the pan. ALWAYS use weighting paper. 2. ONLY mass solids you are instructed to mass. 3. DO NOT move. 4. $483
4
Beaker: Used to mix and heat solutions and mixtures
Beaker: Used to mix and heat solutions and mixtures. It is graduated but is only used for general volumes measurements. Can use with a stirring rod to pour. MUST marked with Pyrex, TEKK or Bomex to be heated.
5
Erlenmeyer Flask: Used to heat and mix solutions and mixtures
Erlenmeyer Flask: Used to heat and mix solutions and mixtures. It is graduated but is only used for general volume measurements.
6
Graduated Cylinders: Used for measure accurate volumes
Graduated Cylinders: Used for measure accurate volumes Volumes are measured at eye level and looking at the meniscus.
7
Funnel: Used to direct flow to transfer liquids from one vessel to another. Funnels are also used in the process called filtration that separate solids from liquids. NOTE: the funnels are plastic and will melt with heat.
8
Test tubes: Used to heat and mix solutions
Test tubes: Used to heat and mix solutions. MUST be tempered glass (Pyrex, TEKK, Bomax, Kimax) to be used in the lab!!!!!!! Test Tube Rack: Used to hold test tubes. Test Tube Clamp: holds test tube while heating
9
Bunsen Burner: Used to heat solutions. outer cone: 600oF
Bunsen Burner: Used to heat solutions outer cone: 600oF middle cone: HOTTEST oF inner cone: 800oF
10
Flint Spark Lighter: Used to light the Bunsen burner
11
Evaporating Dish: Used to heat solids and drive off any moisture.
12
Ring Stand and Ring: Used to support equipment while heating in the lab. Wire Glaze: supports a beaker and spreads the flame evenly. Funnels Clay Triangle: Used to support a crucible
13
Crucible with lid: Used to heat a solid to a very high temperature.
14
Watch Glass: Used to cover the crucible so that you can ‘watch’ the solid. MUST be Pyrex
15
Stirring Rod: Used to stir a solution and to direct flow of a liquid.
16
Wash Bottle: Used to rinse out solid that may stick to the side of the beaker when a precipitate forms between two solutions.
17
Well Plates: Used to mix solutions
18
Thermometer: Used to measure the temperature of a solution or mixture.
19
Dropper Pipets: Used to transfer small volumes of a liquid.
20
Hot Mitts: Used to handle hot glassware
Hot Mitts: Used to handle hot glassware. Remember hot glass and cool glass look alike.
21
Water Bath Set-up: Used to heat or raise the temperature of a substance to the temperature of water.
22
Titration Set-up: Used in a titration
Titration Set-up: Used in a titration. A titration is a procedure used to determine the concentration of a solution, usually an acid or base.
23
Filtration Set-up: Used to separate a liquid from a solid
Filtration Set-up: Used to separate a liquid from a solid. Place the tip of the funnel along the edge of the beaker to prevent splashing.
Similar presentations
© 2025 SlidePlayer.com. Inc.