Rongli Geng March 4, 2015 5th LCC ILC Cavity Group Meeting
JLab Update Rongli Geng March 4, 2015 5th LCC ILC Cavity Group Meeting Inner surface of large-grain niobium cavity G2 under illumination of white LED light. The rich color is a result of interference of light when reflected from the near surface of the niobium. An outstanding grain in the middle of picture reflects the light differently due to presumably its unique grain orientation. Test data of cavity G2 are presented in slide #6. Photo credit: Pashupati Dhakal.
2
High Gradient SRF Themes
Understand and reduce field emission Cavity vertical testing at Epk 100 MV/m Gradient and Q0 degradation due to field emission from vertical testing to operation in cryomoudle CEBAF upgrade cavity experiences Improve efficiency at high and very high gradient New shape – higher R/Q and lower Hpk/Eacc Large-grain material Frozen-in flux (and response to thermal cycling)
3
JLab Status: Field Emission Instrumentation
Installation X-ray sensors (Hamamatsu S ) at all cavities in full FEL cryomodule Compare field emission data at VTA testing with cryomodule testing Establish correlation between FE induced X-ray and FE induced Q0 loss and dark current at end of cryomodule Results reported at TTC meeting at KEK in December 2014. One X-ray sensor for each cavity near beam tube flange F100 cryomodule cavity string being assembled and to be tested
4
JLab Status: High Q0 at 45 MV/m
Two single-cell large-grain niobium cavities under processing and testing for high Q0 at ultra high gradient regime of > 45 MV/m New LSF shape 1-cell large-grain cavities (Two each) In collaboration with Peking University, Ningxia Large grain material. Processing procedure: BCP + 800CX2hr + BCP + 120C bake. Both cavity reached > 35 MV/m and Q0 ~ 2E10 at 2K at max. Eacc. Next step processing using standard ILC recipe: light EP + 120C bake. One new single-cell large-grain niobium cavity under processing and testing Cavity PJ1-2 In collaboration with Peking University and OTIC, Ningxia large-grain Nb material and fabrication. CEBAF upgrade cavity Low-loss shape, 1.5 GHz. Processing procedure: BCP60um+800Cx2hr+BCP60um+HPR+120Cx48hr. Final test result see next slide (reported at AWLC14, , May12-16, 2014) On-going testing for ZFC (Zero Field Cooled) test for mitigation of medium field Q-slope (preliminary result reported at LCWS14, October 6-10, 2014)
6
Progressive EP after N doping
The rise and fall of Q0(Eacc,max) The fall and complete recovery of Eacc, max The necessity of low temperature bake (LTB) for high Q0 at Eacc,max The residual Q0 benefit (+25%) at Eacc=15 MV/m at 30 micron EP, with or w/o LTB