NSTX Supported by NSTX Centerstack Upgrade Project Meeting P. Titus/EA Branch November 17, 2010 Lid/Cover/Flex Aluminum Block Bolting Stress And Stresses with Proposed Reinforcements
2
Offsets Used to Impose Moments Present Configuration
3
Produces High Bolt Stresses for the Upgrade Loads
4
The Upgrade PDR includes addition of a Reinforcing Plate Postulated Weld
5
Tresca Stress in Umbrella Structure Plate Present Configuration Proposed Reinforcement
6
No Reinforcement With Proposed Welded Reinforcement Plate
7
Preloaded Bolt Reinforcement ~90000psi Preload Bolt Stress is About the Same
8
Welds Extend these “Wings”
9
Welds
12
When the OOP force reaches 25% of nominal, the spoke lid springs upward
13
Spoke/Lid/Flex/Von Mises Stress peaks at 17.8ksi
14
Danny’s Crown Tooth Analysis He added a radius and we re- oriented the fiberglass reinforcement – but we need the updated design. Maybe Ali can add In TF Flag Calc?