2 FDA -- Indications For Use
The Neuroform Atlas Stent System is indicated for use with bare metal embolic coils for the treatment of wide-neck intracranial, saccular aneurysms arising from a parent vessel with a diameter of greater than or equal to 2mm and less than or equal to 4.5mm. Wide-neck aneurysms are defined as having a neck greater or equal to 4mm or a dome-to-neck ratio of less than 2.

3 Top Performance Criteria
Designed for all sizes of the stent to be delivered through in (e.g. SL-10) or 0.017in (e.g. XT- 17) microcatheter Design is optimized for conformability Designed for superior deployment ease & accuracy Designed for feature improved coil scaffolding

4 Key Geometry Attributes
Distal Proximal Open cell distal end designed to aid in stent conformability and track 8 cell structural elements designed to provide support and anchoring 12 cell structural elements designed to provide flexibility, improve scaffolding, and prevent ‘gapping’ on a bend Closed cell proximal end designed to aid in stent stability during lumen recross. Neuroform Atlas Neuroform® All photographs taken by Stryker Neurovascular. All illustrations provided by Stryker Neurovascular.

5 Microcatheter Compatibility
All Neuroform Atlas Stent sizes fit through a small microcatheter (0.0165in or 0.017in) From this: 0.027in ID To this: in ID All photographs taken by Stryker Neurovascular.

6 Unique Cell Architecture
Atlas cells are designed to have an improved coil scaffold while retaining microcatheter recrossability. “Nano” Sized Re-crossable All photographs taken by Stryker Neurovascular.

7 Lowest track force required to advance stent
Ease of Access Lowest track force required to advance stent >50% lower track force 4.5 x 30mm Neuroform Atlas + Excelsior® XT-17® Microcatheter 4.5 x 30mm Neuroform Atlas + Excelsior® SL-10® Microcatheter 4.5 x 30mm Neuroform + Excelsior ® XT-27® Microcatheter Data analysis performed by Stryker Neurovascular. Data are on file at Stryker Neurovascular and will be made available upon request.

8 Stent Working Lengths (mm)
4/25/2017 9:40 AM Atlas: Product Matrix Labeled Stent Diameter (mm) Indicated Vessel Range (mm) Unconstrained Stent Diameter (mm) Stent Working Lengths (mm) 3.0 3.5 15 21 24 30 4.0 4.5 5.0 9mm Tip Zero Tip PSST Reference: DIOVV Atlas: NV Tip Photos: NV Nfez 19MM tIP All photographs taken by Stryker Neurovascular. V4

9 Atlas: Unique Scaffold
4/25/2017 9:40 AM Atlas: Unique Scaffold PSST Photo Reference: MCA model: NV Lateral view: NV Hybrid design can conform to anatomy while maintaining recrossability Hybrid design can reduce bifurcation neck Hybrid design can appose on tight curves All photographs taken by Stryker Neurovascular. Sample images represent expected performance of Atlas Stent. V4

10 Disclaimers Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: Excelsior, Neuroform, Neuroform Atlas, Neuroform EZ, SL-10, XT-17, XT-27. All other trademarks are trademarks of their respective owners or holders.