1 CP Violation in Positronium Decay The Pecking Order Lana Del Reyco Chelsea Neutron Joule Kadeem Nibbs

2 Purpose Standard Model predicts Charge-Parity (CP) symmetry (for the most part) CP violation necessary to explain matter- antimatter asymmetry in universe Observed in quark sector, not yet in lepton sector 7/25/20152

3 The Great White Buffalo (Positronium) Bound state of electron and positron (bound state of particle and antiparticle) Singlet (Para-)Triplet(Ortho-) 2 gamma ray decay3 gamma ray decay 125 picosecond lifetime140 nanosecond lifetime No CP observableCP Observable 7/25/20153

4 Detecting CP Violation Angular correlation between spin of ortho- positronium (o-Ps) and directions of emitted gamma rays Asymmetry between positive and negative values of sin2θcosφ θ φ k1k1 k2k2 S 7/25/20154

5 The APEX Array Source Holder Configuration NaI BarPMT 7/25/20155

6 Gamma Ray Detection Gamma ray striking detector causes cascade of scintillation light Light creates current in PMT PMT base creates voltage proportional to current Digitizer records voltages in memory buffer – SIS3301 105Ms/s 7/25/20156

7 Event Reconstruction One way to find position: Light Attenuation (thank you Stephen Daigle) A1A1 A2A2 x0x0 Charge Amplitude from PMT1 Charge Amplitude from PMT2 7/25/20157

8 Possible Issue This can happen: – Gamma ray deposited in inconvenient place – Scintillation light reflected or absorbed by frame of PMT – Skewed ratio of signal strength from each PMT – Bad position reconstruction, false asymmetry measurement 7/25/20158

9 Solution: Additional Position Info Use time of light entering PMTs x t 1 is time light enters PMT 1 t 2 is time light enters PMT 2 Index of refraction of NaI 7/25/20159

10 My Job Extract timing information from waveform (from 22 Na source) Threshold Peak Half-Peak 7/25/201510

11 My Job (Cont.) Blown up portion of waveform from half- peak to baseline Detection Time Baseline Least Squares Line 7/25/201511

12 Results 7/25/201512 Number of Hits Detection Time (Digitizer Cycles)

13 Future Work Use calibrated delay line to test accuracy of my timing reconstruction algorithm Test validity of location reconstruction – Is it close to the light attenuation method in most cases? – Can the two results check each other? 7/25/201513

14 Acknowledgements Reyco Henning Mark Howe Chelsea Bartram Joule Othman Stephen Daigle Chiara Salemi 7/25/201514

15 Energy Spectra: Na22 Source 7/25/201515