Download presentation
Presentation is loading. Please wait.
Published byBrice Junior Oliver Modified over 9 years ago
1
SLHC Local Support Requirements Summary M. Gilchriese November 4, 2008
2
Radiation Levels This is what I assume(6000 fb -1 )….needs update(Dawson) 2 Will be able to validate with data well before designs frozen…
3
Heating Front-end electronics + local cables(Fabian, Maurice) – Nominal: 0.3 W/cm 2 – Maximum: 0.5 W/cm 2 Environmental heating - TBD Needs real calculations and comparison to data from current detector. Non-uniform (convection)….. Sensor heating – See plots on next pages for 3D and n-in-p – Also must estimate leakage current vs temperature. I take 100 nA per pixel as the maximum, which implies a temperature limit for fixed fluence 3
4
3 D Sensor Heating – Input Data Large spread in data – take worst for now 4
5
3D Sensor Heating Extrapolated to -25C for comparison. Should be about linear…. Highest fluence? 5 FluenceW/cm 2 -25C 7.50E+147.00E-04 2.00E+154.50E-03 6.40E+150.006 1.30E+160.022 2.60E+160.08
6
n-in-p Sensor Heating Source: A. Affolder presentation 6
7
Leakage Current n-in-p for 900V 50x250 2 pixel Plot is temperature at which pixel leakage current is 100nA vs power at -25C 3D – remember data spread! Assume 125V Need cold! 7 Achievable with C 3 F 8 ? Max?
8
Mechanical Detailed specifications to be developed but should be guided by alignment experience with current detector. Short term stability ie. within time window for alignment with tracks micron level. This will not change. Vibrational spec. TBD. Thermal and moisture distortions – Current detector(barrel) has large distortions. Will it matter? Need experience! This will take year(s)…OK – In the meantime, design to minimum CTE and CME effects. 8
9
Module Interface Again need alignment experience from current detector. Track-based alignment will be very well developed tool 10 years from now Local support design must allow for…. Placement accuracy 50 microns Local survey accuracy – it’s hard not to do <10 microns on local supports but may not be needed. Interface to global support survey – make it easier. New techniques beyond traditional touch or optical survey in next years? 9
10
Reliability Critical!!!! Detailed requirements for reliability need to be developed. But given our experience… – Radiation up to 10 7 Gy – Number of thermal cycles many hundreds - 1000? – Corrosion or similar effects – Cooling interface – no leaks Design qualification for reliability will be a challenge! Needs much more effort but hard…. 10 Sources for fast radiation to this level? Not easy to do 1000 thermal cycles
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.