Download presentation
Presentation is loading. Please wait.
Published byVirginia Nicholson Modified over 9 years ago
1
NA-MIC - Contrasting Tractography Method Conference Utah/UNC results Sylvain Gouttard Guido Gerig Casey Goodlett Santa Fe, October 1 st & 2 nd 2007
2
Overview Processing description: DWI to tensors ROIs Tracking Bundling / cleaning Results: Fiber tracked FA/MD analysis Conclusion
3
Original Data High resolution DWI with 59 images (8 B0's and 51 directions) size 256*256*81 resolution 0.9,0.9,1.7 Tensor field Tensor estimation using dtiestim: - Linear least square - B0 threshold = 500
4
ROIs 5 ROIs: Arcuate Cingulum Fornix Internal Capsule Uncinate Original ROIs not appropriate for our tractography tool (need volumetric ROIs) Had to specify target and source labels Split right and left
5
ROIs - Arcuate No editing
6
ROIs - Cingulum Original ROIsEdited ROIs
7
ROIs – Fornix Original ROIs Edited ROIs
8
ROIs – Internal Capsule Original ROIs Edited ROIs
9
ROIs - Uncinate Original ROIs Edited ROIs
10
Fiber tracking Fiber tracking done with the FiberTracking tool, based on Susumu Mori's tool. Input: tensor field & ROI Output: Streamlines Parameters: min FA threshold 0.15 angle of max dev 0.35
11
Post processing – FiberViewer Clustering and cleaning bundle cleaning via clustering: Metrics for clustering: fiber length center of mass Hausdorff Fiber cutting
12
Post processing - FiberViewer Diffusion statistics Diffusion statistics for each bundle: Definition of coordinate origin FA MD λ 1,2,3 diffusion val. geodesic distance 0+L-L
13
Specifications Computational resources: 2 Intel Xeon processors 2GHz 2G of RAM linux Average execution time per case: DWI -> tensors: <1min Tractography: 2 < t < 10 min Cleaning: 2 < t < 5 min (manual interaction)
14
Results – High resolution cases 10 cases ( dim:256*256*81 res:0.9,0.9,1.7 ) 5 ROIs ( Arcuate, Cingulate, Fornix, Int. Capsule, Uncinate ) We use the number of streamlines for comparison but know that it is limited
15
Fiber tracking example D00925 ; Internal capsule 19 fibers D00935 ; Internal capsule 740 fibers D00935 cleaned ; Internal capsule ; 545 fibers
16
Fiber tracking example D00920 ; Arcuate ; 29 fibers D00928 ; Arcuate ; 99 fibers
17
Fiber tracking example D00925 Cingulum 2 fibers D00917 ; Cingulum ; 175 fibers D00917 cleaned ; Cingulum ; 170 fibers
18
Fiber tracking example D00925 ; Fornix ; 3 fibers D00928 ; Fornix ; 77 fibers
19
Fiber tracking example D00936 Uncinate 1 fibers D00935 ; Uncinate ; 140 fibers D00935 cleaned ; Uncinate ; 100 fibers
20
Resulting data structure Origin plane manually placed Arc-length parameterization Diffusion values along fibers (FA, MD, λ's,GA) in excel format
21
FA-MD plots - Cingulum FA MD 0.0 0.86 15 0
22
FA-MD plots - Fornix FA MD 0.0 0.75 40 0 Analysis: - 1 branch at a time? - 2 at the same time?
23
FA-MD plots – Internal capsule FA MD 0.0 0.75 15 0
24
FA-MD plots - Uncinate FA MD 0.0 0.80 15 0
25
Evaluation of preprocessing 2 cases with: Orignal data (dim:256*256*81 res:0.9,0.9,1.7) Eddy current correction (dim:256*256*81 res:0.9,0.9,1.7) Eddy current correction and sub sampled (dim:144*144*81 res:1.6,1.6,1.7) # of fibers
26
Evaluation of preprocessing Tensors filtered using MedINRIA tensor smoothing => Inconsistent results Internal Capsule: - Not filtered => 59 fib - Filtered => 179 fib Cingulum: - Not filtered => ~140 fib - Filtered => 0 fib Examples:
27
Summary / Problems ROIs: need redrawing to do tractography with our tools Noise level seems high w.r.t. to streamline tracking High variability across cases => subject specific? scanning artefacts? motion? distortion? ...
28
Summary / Problems (2) Coordinate system inconsistency: ROIs are individually placed FiberViewer: origin plane manually set for statistics Metric for comparison: number of fibers: does not describe quality
30
High resolution cases Percentage of fibers (with Left and Right)
31
High resolution cases Fiber tracked numbers
32
High resolution cases Fiber cleaned numbers
33
Results High resolution cases after cleaning
34
Results – High resolution cases 10 cases ( dim:256*256*81 res:0.9,0.9,1.7 ) 5 ROIs ( Arcuate, Cingulate, Fornix, Int. Capsule, Uncinate )
35
Results High resolution cases after cleaning
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.