Download presentation
Presentation is loading. Please wait.
Published byKristopher Carr Modified over 9 years ago
1
The 2-slot 2U DC chassis is one of a line of products that Asis has developed over the years with it’s vast experience in the ATCA field. Asis AdvancedTCA Class
2
The chassis consist of the following parts : 1.Backplane - 1.Backplane - PCB that connect all the chassis components together. 2.Shelf manager 2.Shelf manager - FRU that control and monitor all of the chassis component.Shelf managerShelf manager 3.Fan tray 3.Fan tray - FRU that supply sufficient air flow and velocity to the shelf in order to withstand within the ATCA specifications. 4.Air filter 4.Air filter - FRU that filter the incoming air in to the chassis 5.SEEPROMs 5.SEEPROMs - FRU which contain data about the chassis and the manufacture. 6.PEM 6.PEM - supplying sufficient DC regulated power to the shelf for operation. 7.Front Blade 7.Front Blade - areas in which the third party blades slide into. 8.RTM areas - 8.RTM areas - areas in which the third party RTM slide into.
3
Asis AdvancedTCA Class 2 - Shelf manager 4 - Air filter 3 - Fan tray 6 - PEM 5 - Rear SEEPROM Cover 7 - Front blade Front View Rear View 8 - RTM insertion area
4
Technical Data: 2-slot 2U AC version 88mm X 448mm X 413.3mm, not including handles & cable holders. Backplane topology - Full mesh Cooling performances : Effective - Cooling capability of 200W per front blade and 20W per RTM. Perform - Cooling capability of 300W per front blade and 30W per RTM. Fan Tray - One Fan Tray, four fans. Power - One Power Entry Module for full chassis power consumption, Optional secondary for full redundancy. Air Filter - One air filter. Asis AdvancedTCA Class
6
In order to get further information about the Chassis Please refer to the chassis user Manual. At www.asis-pro.com, login at the Partners zonewww.asis-pro.com In order to download the manual. Asis AdvancedTCA Class