1 Date:16.12.2015 File:PRO1_18E.1 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation Appendix: Technical Specifications and Special Features of the S7-400

2 Date:16.12.2015 File:PRO1_18E.2 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation Technical Specifications of the S7-300 CPUs (1) CPU Execution time per Binary instruction Load/Transfer (Word) 16 bit integer (+/-) IEEE flaoting pnt (+/-) User memory Work memory Load memory integr. Load memory extern Addresses Bit memories Clock memories Timers Counters Block Types/Number FBs FCs DB's Size of process image (inputs/outputs) max. I/O address area Integral interfaces 314 IFM 300 ns 800 ns 1500 ns <50 µs 32 KB 48 KB - 2048 8 128 64 128 127 124 Byte each 752 Byte each MPI 315-2 DP 300 ns 900 ns 1500 ns <35 µs 64 KB 96 KB 4 MB 2048 8 128 64 192 254 128 Byte each 1024 Byte each MPI, DP 315 300 ns 900 ns 1500 ns <35 µs 48 KB 80 KB 4 MB 2048 8 128 64 192 254 128 Byte each 768 Byte each MPI 312 IFM 700 ns 2400 ns <60 µs 6 KB 20 KB - 1024 8 64 32 127 32 Byte each MPI 314 300 ns 800 nsc 1500 ns <50 µs 24 KB 40 KB 4 MB 2048 8 128 64 128 127 128 Byte each 768 Byte each MPI 313 700 ns 2400 ns <60 µs 12 KB 20 KB 4 MB 2048 8 128 64 128 127 128 Byte each 32 Byte each MPI 316-2 DP 300 ns 900 ns 1500 ns <35 µs 128 KB 192 KB 4 MB 2048 8 128 64 256 512 511 128 Byte each 1024 Byte each MPI, DP 318-2 DP 100 ns 0,6 µs 512 KB 64 KB 4 MB 8192 8 512 1024 2047 256 Byte each 8192 Byte each MPI/DP, DP

3 Date:16.12.2015 File:PRO1_18E.3 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation 313 OB-No. 1 10 20 35 40 - 100 80-82, 85, 87 121,122 1536 Byte 8 KB 8 4 1 22 bytes CPU Organization blocks Free cycle Time-of-day interrupts Time-delay interrupts Cyclic interrupts Hardware interrupts Background execution Startup Errors, asynchronous Errors, synchronous Local data max. Block length Block nesting depth per execution level Program-controlled communication: max. Number of connections Global Data communication via MPI: GD circles per CPU Send GD packets per GD circle Receive GD packets per GD circle max. user data size of a packet Technical Specifications of the S7-300 CPUs (2) 314 IFM OB-No. 1 10 20 35 40 - 100 80-82, 85, 87 121,122 1536 Byte 8 KB 8 4 1 22 bytes 315-2 DP OB-No. 1 10 20 35 40 - 100 80-87 121,122 1536 Byte 16 KB 8 4 1 22 bytes 315 OB-No. 1 10 20 35 40 - 100 80-82, 85, 87 121,122 1536 Byte 16 KB 8 4 1 22 bytes 312 IFM OB-No. 1 - 40 - 100 - 512 Byte 8 KB 8 4 1 22 bytes 316-2 DP OB-No. 1 10 20 35 40 - 100 80-87 121,122 1536 Byte 16 KB 8 4 1 22 bytes 318-2 DP OB-No. 1 10,11 20,21 32,35 40,41 90 100,102 80-87 121,122 4096 Byte 64 KB 16 32 8 1 2 54 bytes 314 OB-No. 1 10 20 35 40 - 100 80-82, 85, 87 121,122 1536 Byte 8 KB 8 4 1 22 bytes

4 Date:16.12.2015 File:PRO1_18E.4 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation Technical Specifications of the S7-400 CPUs (1) *) 1 byte = 8 digital inputs/outputs 2 bytes = 1 analog input/output CPU Execution time per Binary instruction Load/Transfer (word) 16-bit integer (+/-) IEEE floating pnt (+/-) User memory Work memory Load memory integr. Load memory extern Addresses Bit memories Clock memories Timers Counters Block Types /Number FBs FCs DB's Size of Process Image (inputs/outputs) Max. I/O address area Integral interfaces 414-1 100 ns 0.6 µs 128 KB 8 KB 15 MB 8192 8 256 512 1024 1023 256 bytes each 2 Kbyte each *) MPI 416-1 80 ns 0.48 µs 512 KB 16 KB 15 MB 16384 8 512 2048 4095 512 bytes each 4 KByte each *) MPI 414-2 DP 100 ns 0.6 µs 128/384 KB 8 KB 15 MB 8192 8 256 512 1024 1023 256 bytes each 4 Kbyte each *) MPI, DP 412-1 200 ns 1.2 µs 48 KB 8 KB 15 MB 4096 8 256 511 128 bytes each 0.5 Kbyte each *) MPI 413-2 DP 200 ns 200 nsc 200 ns 1.2 µs 72 KB 8 KB 15 MB 4096 8 256 511 128 bytes each 1 Kbyte each *) MPI, DP 413-1 200 ns 1.2 µs 72 KB 8 KB 15 MB 4096 8 256 511 128 bytes each 1 Kbyte each *) MPI 416-2 DP 80 ns 0.48 µs 0.8/1.6 MB 16 KB 15 MB 16384 8 512 2048 4095 512 bytes each 8 KByte each *) MPI, DP 417-4 100 ns 0.48 µs 4...20 MB 256 KB 64 MB 16384 8 512 6144 8191 1024 bytes each 16 KByte each *) MPI, 4 x DP

5 Date:16.12.2015 File:PRO1_18E.5 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation CPU Organization blocks Free cycle Time-of-day interrupts Time-delay interrupts Cyclic interrupts Hardware interrupts Multicomp. interrupt Background execution Startup Errors, asynchronous Errors, synchronous Local data Max. block length Block nesting depth per execution level Program-controlled communication: max. number of connections Global data communication via MPI: GD circles per CPU Send GD packets per GD circle Receive GD packets per GD circle Max. user data size of a packet Technical Specifications of the S7-400 CPUs (2) 414-1 OB No. 1 10-13 20-23 32-35 40-43 60 90 100-102 80-87 121,122 8 KB 64 KB 16 32 8 1 2 54 bytes 416-1 OB No. 1 10-17 20-23 30-38 40-47 60 90 100-102 80-87 121,122 16 KB 64 KB 16 64 16 1 2 54 bytes 414-2 DP OB No. 1 10-13 20-23 32-35 40-43 60 90 100-101 80-87 121,122 8 KB 64 KB 16 32 8 1 2 54 bytes 412-1 OB No. 1 10,11 20,21 32,35 40,41 60 90 100-102 80-87 121,122 4 KB 64 KB 16 8 1 2 54 bytes 413-2 DP OB No. 1 10,11 20,21 32,35 40,41 60 90 100-102 80-87 121,122 4 KB 64 KB 16 8 1 2 54 bytes 413-1 OB No. 1 10,11 20,21 32,35 40,41 60 90 100-101 80-87 121,122 4 KB 64 KB 16 8 1 2 54 bytes 416-2 DP OB No. 1 10-17 20-23 30-38 40-47 60 90 100-102 80-87 121,122 16 KB 64 KB 16 64 16 1 2 54 bytes 417-4 OB No. 1 10-17 20-23 30-38 40-47 60 90 100-102 80-87 121,122 24 KB 64 KB 24 64 16 1 2 54 bytes

6 Date:16.12.2015 File:PRO1_18E.6 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation Main Differences to the S7-300  Larger memory and more I/Q/M/T/C  Addresses of input/output modules selectable  Can connect EUs from S5 and use S5 CP/IP modules  More system functions, e.g. programmed block communication  Block size up to 64KB and twice as many DBs  Complete restart and restart  Preset/actual comparison of configuration on startup  Modules can be removed without disconnecting the power supply  Several part process images  Priorities of OBs are parameter-assignable  Several OBs for cyclic, hardware and time-of-day interrupts  Block nesting up to 16 levels  Size of L Stack selectable for each execution level  4 accumulators  Multicomputimg

7 Date:16.12.2015 File:PRO1_18E.7 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation Components of the S7- 400 CPUs CPU 412-1 CPU 413-1, 413-2 CPU 414-1, 414-2, CPU 416-1, 416-2 CPU 417-4 Racks - Universal rack (UR 1/2) for use as CR and ER - Extension rack (ER 1/2) - Segmented central rack (CR2) Signal modules (SM) - DI/DO 32,16,8 channels - DO wit h relay output - AI/AO 16,8 channels - diagnostics-capable modules Communication processors (CP) Communication processors (CP) - Point-to-Point CP441-1, 1- channel CP441-2, 2- channel - Networks Profibus Ethernet Power supplies (PS) - AC 120V/230V, 4A/10A/20A - DC 24V, 4A/10A/20A Function modules (FM) Function modules (FM) - Counting - Positioning - Closed-loop control

8 Date:16.12.2015 File:PRO1_18E.8 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation Racks of the S7 - 400 UR1 / UR2 (Universal Rack) Type of Rack Central rack Extension rack Usable in Yes P bus ER1 / ER2 (Extension Rack) NoYes P bus K bus CR2 (Central Rack) NoYes P bus, Segment 1 K bus P bus, Segment 2

9 Date:16.12.2015 File:PRO1_18E.9 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation Module Parameters: Logical Addresses

10 Date:16.12.2015 File:PRO1_18E.10 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation CPU Parameters: Startup

11 Date:16.12.2015 File:PRO1_18E.11 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation CPU Parameters: Interrupts

12 Date:16.12.2015 File:PRO1_18E.12 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation CPU Parameters: Local Data

13 Date:16.12.2015 File:PRO1_18E.13 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation Configuring Multicomputing Operation

14 Date:16.12.2015 File:PRO1_18E.14 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation SFC 35 for Synchronization in Multicomputing Operation ParameterDeclarationData typeMemory Description JOBINPUTBYTE I, Q, M, D, L, Const.Task identifier (possible values: 1 to 15) RET_VALOUTPUTINT I, Q, M, D, LReturn value (error code).

15 Date:16.12.2015 File:PRO1_18E.15 SIMATIC S7 Siemens AG 1999. All rights reserved. Information and Training Center Knowledge for Automation Remove and Insert Interrupt Module exists Module available Remove/Insert interrupt Parameter assignment of module through the operating system Removing a module Inserting a module max. 1s max. 1s