Presentation is loading. Please wait.

Presentation is loading. Please wait.

Doppler Free LASER Spectroscopy

Similar presentations


Presentation on theme: "Doppler Free LASER Spectroscopy"— Presentation transcript:

1

2 Doppler Free LASER Spectroscopy
It’s a headache for you And a migraine for me!

3 LASER Spectroscopy Setup
Tunable diode LASER

4

5 LASER Spectroscopy Setup
Tunable diode LASER Diffraction grating mirror Piezo-electric actuator

6

7 LASER Spectroscopy Setup
Tunable diode LASER Diffraction grating mirror Piezo-electric actuator Miscellaneous Optics Beam-splitter – splits LASER beam into two probe beams (weak) and a pump beam (strong)

8

9 LASER Spectroscopy Tunable diode LASER Miscellaneous Optics
Diffraction grating mirror Piezo-electric actuator Miscellaneous Optics Beam-splitter – splits LASER beam into two probe beams (weak) and a pump beam (strong) Mirrors – reflect stronger pump beam to counter-propagate against probe beam

10

11 Rubidium cell Probe, reference, and pump beams pass through Rubidium atoms

12

13 Photodiode differential amplifier
Rubidium cell Probe, reference, and pump beams pass through Rubidium atoms Photodiode differential amplifier Subtracts the two signals from the reference and probe beams

14

15 Output to Oscilloscope
I made this! Mathmagical Manipulation! Probe beam Output to Oscilloscope Reference beam

16 Photodiode differential amplifier
Rubidium cell Probe, reference, and pump beams pass through Rubidium atoms Photodiode differential amplifier Subtracts the two signals from the reference and probe beams Oscilloscope Creates a real-time plot of “absorption” vs. frequency

17

18 The Statistical Doppler Effect
Gaussian distribution of velocities Fast moving atoms

19

20 The Statistical Doppler Effect
Gaussian distribution of velocities Fast moving atoms Slow moving (stopped) atoms

21

22 The Statistical Doppler Effect
Gaussian distribution of velocities Fast moving atoms Slow moving (stopped) atoms blurring of the spectral lines

23

24

25 How Saturation Spectroscopy Undoes the Doppler Blurring Effects
Reference beam: Passes through only Rubidium Interacts with all the atoms in its path

26

27 How Saturation Spectroscopy Undoes the Doppler Blurring Effects
Reference beam: Passes through only Rubidium Interacts with all the atoms Probe beam: Passes through Rubidium

28

29

30 How Saturation Spectroscopy Undoes the Doppler Blurring Effects
Reference beam: Passes through only Rubidium Interacts with all the atoms Probe beam: Passes through Rubidium and “pump beam” Pump beam:

31

32 How Saturation Spectroscopy Undoes the Doppler Blurring Effects
Reference beam: Passes through only Rubidium Interacts with all the atoms Probe beam: Passes through Rubidium and “pump beam” Pump beam: Counter-propagates through probe beam and excites the atoms in its path Ignores “stationary” atoms at transition frequency because they are already excited by the pump beam

33

34

35

36

37 Application Use the LASER, which is now accurately locked on a precise frequency, to trap atoms Instead of using multiple LASERs, feed the locked LASER beam into a tapered amplifier

38 The Tapered LASER Amplifier
Requirements: Delicate temperature control Input beam Drives the amplifier at the given frequency

39 I made this too! Temperature measuring device (thermistor)
Thermal Electric cooler LASER diode current supply Amplification Process Unthinkably powerful output beam Super stable seed beam LASER diode chip

40 Partially reflective mirror
Excited State Partially reflective mirror Gain Medium (semiconductor) Ground State

41 Gain Medium (semiconductor)
Excited State Gain Medium (semiconductor) Ground State

42


Download ppt "Doppler Free LASER Spectroscopy"