Download presentation
Presentation is loading. Please wait.
Published byPenelope Dennis Modified over 9 years ago
1
TPC ExB distortion at LHC-ALICE experiment Yasuto Hori for the ALICE-TPC collaboration Center for Nuclear Study, University of Tokyo 1
2
Outline 2 Introduction: ALICE-TPC and ExB distortion Calculation technique of ExB distortion Many kinds of ExB distortion ExB Twist distortion Summary and Outlook
3
Overview of ALICE-TPC 100kV A side ROC C side (muon-side) ROC E field Main central tracking device diameter x length = 5 m x 5 m,| | < 0.9, 2 azimuthal coverage Max drift length ~ 2.5 m, Central electrode ~100kV E ~ 400V/cm gas Ne-CO 2 -N 2 (85.7%:9.5%:4.8%) low diffusion & high drift velocity(drift time 92 sec), but strong temperature dependent drift velocity temperature stability & homogenity < 0.1K cooling system and P,T monitor UV laser system used for drift velocity, ExB, alignment B field beam IP z gx gy UV Laser tracks in TPC drift volume 3
4
ExB distortion in ALICE-TPC E &B field Drift electrons Track Pad plane Distorted drift electron Electrons are drifted at the E field direction if ExB is zero. If ExB is non-zero Space point distortion on the Pad plane (or x-y, r- phi) occurs This distortion may degrade DCA-to-Vertex distribution, DCA-btw-2tracks distribution, ITS-TPC matching efficiency,.. Gating Grid wire
5
Calculation technique via Langevin equation Langevin eq. which describes this distortion can be decomposed into E field part and B field part if Ez ≫ Er,E & Bz ≫ Br,B We have to know parameter T 1, T 2 of Ne:CO 2 :N 2 Next slide 5 E field distortionB field distortion Space point distortion Decompose + tensor Steady-state langevin eq
6
T 1, T 2 extraction via Laser track distortion with Gating Grid Voltage (GGV) Scan Procedure 1.Calibrate Voltage at GG plane by measuring C 1 &C 0 using B=0 laser tracks ( C 1 &C 0 must be 0 & 1 at B=0 ) 2. Measure change of track distortion with GGV scan at B=5kGaus 3. Compare with calculation using T 1 and T 2 T 1 = 1.0 +- 0.1, T 2 =1.0 +-0.3 is obtained! Z [cm] Radi [cm] 6 Zigzag pattern of Real data is from Pad geometry T 1 = 1.0 T 2 = 1.0 GGV= 10 V dr [cm] Radi [cm] Distortion change [cm]
7
ExB distortion Sources and Models 7 B field non-uniformity B field is measured, non-zero Br, B , corrected to ~0.3mm Twist between E and B field axis TPC is tilted from the B field axis E field distortion by misalignment of TPC components ( field cage, each rod, ROC, central electrode ) GGV Error from normal setting E field distortion because of space charge Next 3 slides gX [cm] gY [cm] dr [mm] dr [mm] R [cm] Z [cm] B field E field TPC
8
Twist between E and B axis space point distortion ∝ drift length and angle between E and B axis track distortion is similar to translation, but A side track is translated to the opposite direction of C side track translation gX[cm] gY[cm] Z[cm] dr [cm] dr [cm] Zdrift = 250 cm 8 R [cm] Value to be measured
9
A/C vertex shift due to ExB Twist By ExB Twist Distortion, x-y position of vertex reconstructed by only A side tracks is shifted from that of only C side tracks 9 fast simulation full simulation (small statistics) TPC pad plane Distorted A track Original track Distorted C track A/C Vertex shift Inner wall Outer wall A/C vertex shift is almost proportional to Twist angle !!
10
Twist angles extraction and verification at p+p collision data 10 A/C vertex shift can be found at pp collision data! Position of A /C vertex are swapped with B field polarity Primary vertex (by ITS&TPC all tracks) lays on the middle of the A/C vertex Twist angles are extracted and verified !! A vertex C vertex B positive data B negative data A Vertex C Vertex Primary Vertex Non corrected Vertex shift [cm] Extracted x[mrad] Extracted y[mrad] B pos.0.312-2.3-0.40 B neg.0.33-1.7-0.94 Corrected Vertex shift [cm] 0.04 0.03
11
Summary and Outlook 11 We construct framework for calculation of ExB distortion T 1 &T 2 values are extracted by Laser track distortion with GGV scan List up many kinds of ExB distortion ExB distortion due to B non-uniformity is already corrected ExB Twist distortion is measured via A/C vertex shift in p+p collision real data measure A/C ROC rotation and translation, which causes A/C vertex shift estimate how Rods shift (dominant part of E field distortion) causes A/C vertex shift finalize Twist angles ExB due to E field distortion like Rods shift, … Space charge at PbPb collision data
12
- back up - 12
13
Misalignment between A side ROC & C side ROC dY dX dd 13
14
T 1, T 2 parameters measurement via Laser track distortion with Gating Grid Voltage (GGV) Scan 1 Change Gating Grid Voltage from normal setting ~ 70Volt Change “effective” voltage at GG plane “effective” means that voltage at GG plane depend on GGV setting itself as well as E field leakage from under GG plane E field distortion change ExB space point distortion change, which can be observed by laser tracks and calculated using T 1 and T 2 parameters Z [cm] Radi [cm] 14 Zigzag pattern of Real data is from Pad geometry T 1 = 1.0 T 2 = 1.0 GGV= 10 V dr [cm] Radi [cm] Distortion change [cm]
15
T 1, T 2 parameters measurement via Laser track distortion with Gating Grid Voltage (GGV) Scan 2 “effective” voltage at GG plane can be calculated by garfield simulation GGV eff [V] = 0.9175*GGV setting [V]+ 3.91 This can be confirmed by measuring C 0 & C 1 value at B=0 data, which must be 1 & 0 Reasonable agreement (left chi2 plot) 15 With above relation, T 1 &T 2 values are extracted by B=5kGaus laser data T 1 = 1.0 +- 0.1 T 2 = 1.0 +- 0.3 Good agreement with garfield simulation
16
16 Sigma of DCA-to-Vertex distribution with 2 sets of correction parameters. Black line is almost consistent to MC With Old corr. With New corr.
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.