1 ConfidentialConfidential Electromagnetic Type Digital Flow Switch LFE Series Integrated display type Separated type Sensor Display

2 ConfidentialConfidential 1. Purpose of development For flow control of cooling water for moulding and welding guns and leakage control tip cooling water, the liquid which is measured by flow meter is mainly industrial water. Flow meter types such as float, impeller or Karman vortex are used, but they all have problems with clogging. ↓ (1) Small pressure loss (2) No clogging (3) Small flow meter for liquid Require development

3 ConfidentialConfidential 2. Features (1) No obstacles in the fluid path. Compact and lightweight. Smooth fluid path with no moving parts is resistant to clogging. Light weight ⇒ 340g ( value for LFE1*3)

4 ConfidentialConfidential 2 . Features (2) Low pressure loss (0.02MPa or less) (for LFE1 and LFE2) LFE1 LFE2 LFE3 Pressure loss (MPa) 0.04 0.03 0.02 0.01 0.00 Flow rate (L/min) 0 5 10 15 20 Pressure loss (MPa) 0.04 0.03 0.02 0.01 0.00 Flow rate (L/min) 0 20 40 60 80 100 Pressure loss (MPa) 0.04 0.03 0.02 0.01 0.00 Flow rate (L/min) 0 50 100 150 200

5 ConfidentialConfidential Backflow can be detected 2 . Features (3) Flow direction can be changed after installation Normal flow. (Left --> Right) Backflow (Right --> Left) IN OUT Normal flow. (Left --> Right) Backflow (Right --> Left) Backflow error displayed

6 ConfidentialConfidential 3 colour, 2 display indication Example of lower screen (Upper screen is for instantaneous flow rate) Upper screen Lower screen (Lower screen) Set value Accumulated Peak/ bottom Line name value value 2. Features (4) Wide range (Wide rated flow range)  LFE1 : 0.5 to 20 L/min  LFE2 : 2.5 to 100 L/min  LFE3 : 5 to 200 L/min

7 ConfidentialConfidential 3. Applications Flow control of cooling water for welding gun, leakage control of tip cooling water. Flow control for cooling water for mold Flow control for aqueous coolant

8 ConfidentialConfidential 4. Specifications and Performance (1) ModelLFE1LFE2LFE3 Applicable fluidWater or liquids which do not corrode the fluid contact materials. Applicable electrical conductivity  5 μS/cm Rated flow range0.5 to 20.0 L/min2.5 to 100.0 L/min5 to 200 L/min Display and settable value range 0.4 to 24.0 L/min2.0 to 120.0 L/min4 to 240 L/min Min. setting unit0.1 L/min0.5 L/min1 L/min Accumulated flow range 99999999.9 L999999999 L Repeatability Display value: +/-2 % F.S. analog output: +/-1.5 % F.S. Operating fluid temperature 0 to 85 o C (No freezing or condensation) Ambient temperature0 to 50 o C (No freezing or condensation) Temperature characteristics +/-5 %F.S. (25 o C reference) Operating pressure range 0 to 1 MPa Proof pressure2 MPa Integrated display type (1)

9 ConfidentialConfidential 4 . Specifications and Performance (2) ModelLFE1LFE2LFE3 Switch outputNPN or PNP open collector Max. load current: 80mA, max. applied voltage: 28V Analogue output Voltage output 1 to 5V (Output impedance 1kΩ) Current output 4 to 20 mA (Maximum load impedance 600Ω) Response timeCan be selected from 0.25 s, 0.5 s, 1s, 2s, and 5s. (63% response) Display type 2 screen display Upper screen: 7seg 4 digits Red / Green 2 colors Lower screen: 11seg 6 digits White Operation LEDOutput 1, 2 orange Power supply voltage24V DC +/-10% Current consumption45 mA or less (Load current is not included) EnclosureIP65 ComplianceCE marking, RoHS Materials of fluid contact parts PPS 、 FKM 、 C37 Port size3/8inch(10A)1/2inch(15A)3/4inch(20A)1inch(25A) Weight340 g400 g520 g680 g Integrated display type (2)

10 ConfidentialConfidential 4 . Specifications and Performance (3) ModelLFE1LFE2LFE3 Applicable fluidWater or liquids which do not corrode the fluid contact materials. Applicable electrical conductivity  5 μS/cm Rated flow range0.5 to 20.0 L/min2.5 to 100.0 L/min5 to 200 L/min RepeatabilityAnalogue output: +/-1.5%F.S. Operating fluid temperature 0 to 85 o C (No freezing or condensation) Ambient temperature 0 to 50 o C (No freezing or condensation) Temperature characteristics +/-5 %F.S. (25 o C reference) Operating pressure range 0 to 1 MPa Withstand pressure2 MPa Remote type sensor (1)

11 ConfidentialConfidential 4 . Specifications and Performance (4) ModelLFE1LFE2LFE3 Analogue output Respons e time 0.5 s Voltage output 1 to 5V (Output impedance 1kΩ) Current output 4 to 20 mA (Maximum load impedance 600Ω) Power supply voltage24V DC +/-10% Current consumption42 mA or less (Load current is not included) EnclosureIP65 ComplianceCE marking, RoHS Materials of fluid contact parts PPS 、 FKM 、 C37 Port size3/8inch(10A)1/2inch(15A)3/4inch(20A)1inch(25A) Weight335 g395 g515 g675 g Remote type sensor (2)

12 ConfidentialConfidential 4 . Specifications and Performance (5) ModelLFE0 Display range0.4 to 24.0 L/min2.0 to 120.0 L/min4 to 240 L/min Min. setting unit0.1 L/min0.5 L/min1 L/min Accumulated flow range99999999.9 L999999999 L Accuracy Display value: +/-0.5 % F.S. Analogue: +/-0.5 % F.S. Repeatability0.5%F.S. Operating temperature range 0 to 50 o C (No freezing or condensation) Temperature characteristics +/-0.5 %F.S. (25 o C reference) Separate monitor (1)

13 ConfidentialConfidential 4 . Specifications and Performance (6) ModelLFE0 Switch outputNPN or PNP open collector Max. load current: 80mA, max. applied voltage: 28V Analogue output Voltage output 1 to 5V (Output impedance 1kΩ) Current output 4 to 20 mA (Maximum load impedance 600Ω) Response timeCan be selected from 0.5 s, 1s, 2s, and 5s. (63% response) Input and outputInput for copy mode Display type 2 screen display Upper screen: 7seg 4 digits Red / Green 2 colors Lower screen: 11seg 6 digits White Operation LEDOutput 1, 2 orange Power supply voltage24V DC +/-10% Current consumption50mA or less (Load current is not included) EnclosureIP40 (Note that only the display front is certified as IP65 by using optional panel mount adapter and waterproof seal). ComplianceCE marking, RoHS Weight50 g Separate monitor (2)

14 ConfidentialConfidential 5 . Construction (Sectional view) Electrode Coil Seal (FKM) Attachment (C37) Pipe (PPS) Body (PBT) M12 connector

15 ConfidentialConfidential 5 . Construction (Sectional view) Electrode Coil Seal (FKM) Attachment (C37) Pipe (PPS) Body (PBT) M12 connector

16 ConfidentialConfidential 【 SMC 】【 TT 】 Series nameLFE series (Integrated type)FD-M series ModelLFE1LFE2LFE3FD-M10FD-M50FD-M100 Detecting methodElectromagnetic flow meter with Electrostatic capacity Rated flow range [L/min] 0.5 to 202.5 to 1005 to 2000.5 to 102.5 to 505 to 100 Display and setting range [L/min] 0.4 to 242.0 to 1204 to 2400.5 to 302.5 to 1005 to 200 Fluid temperature characteristic [%F.S.] +/-5 % (25 o C reference)Not known Fluid temperature range: 0 to 85C o Response time [s]Available from 0.25, 0.5, 1, 2, and 5Available from 0.5, 1, 2.5, 5, 10, 30, and 60 Repeatability [%F.S.] +/-20.5s: +/-5, 1s:+/-3.5, 2.5s: +/-2.5 5s: +/-1.6, 10s:+/-1, 30s: +/-0.8 60s : +/-0.6 Dimensions [mm] (W×H×L) 40×56 ×90 50 x 67 x 105 55 x 73 x 120 56 x 54.1 x 110 65×65.1 ×120 70×71.1 ×130 Weight (g)34052068085311001310 6 . Comparison with competitors

17 ConfidentialConfidential 7 . How-to-Order (1) Integrated type sensor Rated flow range Sym bol Rated flow range 10.5 to 20 L/min 22.5 to 100 L/min 35 to 200 L/min Sym bol OUT JAnalogue 1 to 5V KAnalogue 4 to 20 mA LFE1A3 Output spec. Port size Sym bol OUT1OUT2 ANPN BPNP CNPNAnalogue 1 to 5V DNPNAnalogue 4 to 20 mA Thread type Sym bol Port sizeApplicable models LFE1LFE2LFE3 3 3/8 inch ● - - 4 1/2 inch ● - - 6 3/4 inch - ● - 8 1 inch - -● Remote type sensor LFE1J3 Option Output spec. Symbol M12 connector Lead wire (Length 3m) Bracket Unit specificati on Nil ● - L/min 1-- 2 ●● 3- ● 4 ● - Gal/min 5-- 6 ●● 7-● Symbol NilRc NNPT FG

18 ConfidentialConfidential Separate monitor 7 . How-to-Order (2) Type 0Separate monitor LFE0A - MVC Output spec. Symbol OUT1OUT2 ANPN BPNP CNPNAnalogue 1 to 5V DNPNAnalogue 4 to 20 mA Lead wire Option 2 Option 1 Symbol Nil With lead wire for power supply/ output NWithout lead wire for power supply/ output Symbol NilNone TPanel mount adapter VFront protective cover + Panel mount adapter Symbol NilWithout connector CSensor connector (1 pc.) Unit specification Symbo l Instantaneous flow Accumulated flow ML/minL GGal/mingal

19 ConfidentialConfidential 8 . Dimensions (1) A B C D E F G 2 x port size H I J 4 x K Symbol Model Piping Port size ABCDEFGHIJK LFE1□3 3/890734023.5568389245228F2.5 depth 5.5 LFE1□4 1/2104734023.5568389285228F2.5 depth 5.5 LFE2□6 3/41057850296794100355638F2.5 depth 5.5 LFE3□8112090553273100106416843F2.5 depth 5.5 (Dimensions for remote type sensor are the same as display integrated type.) Dimensions for display integrated type and remote type sensor

20 ConfidentialConfidential 8 . Dimensions (2) 40 □36.8 40.1 6 (7.5) 2.5 53 47 46.4 □42.4 Front protective cover Water proof seal Panel Panel mount adapter 9.2(2) Dimensions for separate monitor Front protective cover + Panel mount adapter

21 ConfidentialConfidential Completely fill the fluid passage with water. The product cannot measure correctly if the fluid passage is not completely filled. If the product is installed vertically, do not apply flow from the top to bottom. Bubbles may cause malfunction. Ensure the product is used within the operating temperature range. Operating temperature range is 0 to 50 o C, fluid temperature range is 0 to 85 o C. When multiple sensors are used in parallel, install them outside of the area shown below. 9 . Cautions for handling (1) 50mm 20mm Uninstallable area

22 ConfidentialConfidential Positive ground power supply cannot be used. Short-circuit DC(+) DC (-) OUT1 OUT2 DC(+) The switch cannot be used for equipment in which piping or installation side is connected to DC(+). In order to identify ground, use a voltage tester and place it on the control board power source DC(-) and the tubing. If the measured voltage is 0V then it is a negative ground. If the measured voltage is 24V then it is a positive ground. Always assure that the customer is advised of this measuring method. Piping port and the metal part of the body are grounded to DC(-)/ blue line. 9 . Cautions for handling (2)

23 ConfidentialConfidential 9 . Cautions for handling (3) Use liquid with 5μS/cm or higher electrical conductivity. This product cannot be used for fluids with low electrical conductivity. This product cannot be used for fluids that do not conduct electricity such as gas, de-ionized water and oil. Fluid Applicability Note Water ○ Conductivity of tap water: 100 to 200μS De-ionized water X Electrical conductivity is low Aqueous coolant ○ When water ratio is more than 50% Oil X Electrical conductivity is low Oil based coolant X Electrical conductivity is low Sea waterXFluid contact part is corroded GALDEN R X Electrical conductivity is low. Fluorinert TM X Electrical conductivity is low. GALDEN R is a registered trademark of Solvay Solexis, and Fluorinert TM is a registered trademark of 3M.

24 ConfidentialConfidential Please download the manual for this product from the SMC World Website Please be aware that the manual is not included with the product. Please download the manual from the following website. http://www.smcworld.com/manual/en 9 . Cautions for handling (4)

25 ConfidentialConfidential 9. Cautions for handling (5) For reference Industrial water Rain water Deionized water Ultra pure water Distilled water Tap water Water base coolant CPEP MP 0.055μS/cm LFE series PF3W series Foreign matter may be in fluid. Prevention against clogging is desired. ↓ LFE series has smooth fluid passage. Clean water is used. There should be no clogging. ↓ Compact PF3W series is recommended. User Electrical conductivity of liquid Electrical conductivity of fluids (Reference) 0.1μS/cm1μS/cm10μS/cm100μS/cm 1000μS/cm Differentiate from close product (Karman vortex type: PF3W series.

26 ConfidentialConfidential 10 . Definition and terminology Electric conductivity Electrical conductivity is a measure of how well electricity flows. Unit is "S/cm (Siemens/ centimeter)". Reference) Tap water 100 to 200μS/cm (5 to 10Ω ・ cm) Distilled water Approx. 5μS/cm (200Ω ・ cm)

27 ConfidentialConfidential 11 . Summary Compact and light weight. No obstacles or moving parts in the fluid passage.  Resistant to dust or clogging.  Low pressure loss. Backflow can be detected. Flow direction can be changed after installation Good visibility  3 colour 2 display indication shows instantaneous flow rate and the set value simultaneously. Wide range Quick response. High repeatability.

28 ConfidentialConfidential Q&A (1) Gas fluid can be measured. (2) All types of coolant liquid can be measured. (3) Contaminated liquid may cause clogging. Filter is necessary. (4) Instantaneous flow and set value are displayed simultaneously. (5) Both integrated type and separated type can detect backflow. (6) If the product is installed vertically, do not apply flow from the top to bottom. Bubbles may cause malfunction. (7) Response time is fixed to 1s. (8) Maximum display and set values are the same as rated flow range. (9) Product can be used with any piping condition. (10) Electrical conductivity is a measure how well electricity flows.