Descemet-Stripping Automated Endothelial Keratoplasty Grafts Prepared from Endothelial Side Using a 500 kHz Femtosecond Laser: Six-Month Outcomes Jesper Hjortdal, Anders Ivarsen, Kim Nielsen Department of Ophthalmology, Aarhus University Hospital, Denmark The authors have no financial interest in the subject matter of this poster
2
Problem DSAEK grafts are usually cut by a micro-keratome or a femtosecond laser after the epithelial side of the donor cornea has been applanated This approach result in – variable central graft thickness in different grafts – an increase in graft thickness towards the periphery in every graft Donor cornea with epithelial side up Applanated cornea during cutting Resulting DSAEK graft of non-uniform thickness
3
New approach If DSAEK grafts can be prepared from the endothelial side by a femtosecond laser, reproducible, thin grafts of even thickness can be produced Donor cornea with endothelial side up Cutting using FS-laser with concave applicator Resulting DSAEK graft of uniform thickness Concave applicator of the Visumax femtosecond laser Concave applicator of the Visumax femtosecond laser
4
Graft Preparation Zeiss-Meditec Visumax 500 kHz FS laser 7.5 mm diameter 130 m thickness #1 FS-laser cutting of DSAEK graft #2 Breaking remaining tissue bridges
5
Patients & Surgery 10 patients with Fuchs endothelial dystrophy Age range: 54 to 78 years of age 5 patients had also phaco + PCIOL Standard DSAEK with Busin glide + forceps #3 DSAEK graft in Busin glide
6
Results – First week Rebubbling necessary in 5 of 10 cases (normally only in 1 of 10 cases) All grafts were attached and clearing up after one week 3 months after implantation of a DSAEK graft prepared from endothelial side
7
Results – Visual Acuity (4-6 months) (Decimal units) Average: 0.30 Range: 0.16 to 0.50 Note shadows in red reflex due to interface haze 3 months after implantation of a DSAEK graft prepared from endothelial side
8
Corneal Thickness (4-6 months) Average: 0.58 mm Range: 0.51 to 0.63 mm DSAEK graft prepared with Moria ALK keratome (for comparison) (Pentacam HR) DSAEK graft prepared with Visumax FS-laser from endothelial side (Pentacam HR) Note uniform thickness, but interface haze of FS-laser prepared graft
9
Endothelial Cell Count (4-6 months) Average: 1.570 /mm 2 Range: 1.400 to 2.000 /mm 2
10
Scanning Electron Microscopy FS-Laser Moria ALK Note laser spots in FS-laser prepared graft
11
Conclusions DSAEK grafts can be prepared from endothelial side using a femtosecond laser 10 of 10 grafts clear after 4-6 months Satisfying endothelial cell count Poor visual acuity due to scatter in interface from laser spots FS-Laser settings need to be fine-tuned Acknowledgement: Jacques Chevallier, Dept. of Physics and Astronomy, Univ. of Aarhus for SEM imaging