1 OF 22 INFO:This is an exterior entry door. The door cannot be locked. There are two deficiencies. DEF: Damaged Hardware/Locks (Doors) - L3 Damaged Surface.

Similar presentations


Presentation on theme: "1 OF 22 INFO:This is an exterior entry door. The door cannot be locked. There are two deficiencies. DEF: Damaged Hardware/Locks (Doors) - L3 Damaged Surface."— Presentation transcript:

1 1 OF 22 INFO:This is an exterior entry door. The door cannot be locked. There are two deficiencies. DEF: Damaged Hardware/Locks (Doors) - L3 Damaged Surface (Holes/Paint/Rusting/Glass Doors) - L3 BUILDING EXTERIOR

2 2 OF 22 INFO: You see peeling and cracking on this exterior entry door. BUILDING EXTERIOR DEF: Damaged Surface (Holes/Paint/Rusting/Glass Doors) - L3

3 3 OF 22 INFO: Exterior door. BUILDING EXTERIOR DEF: Damaged Surface (Holes/Paint/Rusting/Glass Doors) - L3

4 4 OF 22 INFO:There are two deficiencies. DEF: Damaged/Missing Screen/Storm/Security Door - L1 Damaged Surface (Holes/Paint/Rusting/Glass Doors) - L3 BUILDING EXTERIOR

5 5 OF 22 INFO:The crack is > 3/8” width x 3/8” depth x 27” long. BUILDING EXTERIOR DEF:Cracks/Gaps (Foundations) - L3

6 6 OF 22 INFO:There are two deficiencies. 15% of the wall is affected. DEF:Spalling/Exposed Rebar (Foundations) - L2 Cracks/Gaps (Walls) – L2 BUILDING EXTERIOR

7 7 OF 22 INFO:Exposed rebar. BUILDING EXTERIOR DEF:Spalling/Exposed Rebar (Foundations) - L3

8 8 OF 22 INFO:There has been no rain for 3 days. BUILDING EXTERIOR DEF:Damaged/Clogged Drains (Roofs) - L3

9 9 OF 22 INFO:None. BUILDING EXTERIOR DEF:Damaged Soffits/Fascia (Roofs) - L3

10 10 OF 22 INFO:This is the only place on this painted building where you observe this condition. DEF:Missing/Damaged Components from Downspout/Gutter (Roofs) - L3 BUILDING EXTERIOR

11 11 OF 22 INFO:None. DEF:Missing/Damaged Components from Downspout/Gutter (Roofs) – L2 BUILDING EXTERIOR

12 12 OF 22 INFO:You observe this condition and it has not rained for four days. Drain is functional. DEF:Ponding (Roofs) - L3 BUILDING EXTERIOR

13 13 OF 22 INFO:None. BUILDING EXTERIOR DEF:Missing/Damaged Shingles (Roofs) – L1

14 14 OF 22 INFO:None. BUILDING EXTERIOR DEF:Cracks/Gaps (Walls) – L3

15 15 OF 22 INFO:None. BUILDING EXTERIOR DEF:Missing Pieces/Holes/Spalling (Walls) – L3

16 16 OF 22 INFO:None. BUILDING EXTERIOR DEF:Missing Pieces/Holes/Spalling (Walls) – L3

17 17 OF 22 INFO:This is the only damage on this building wall. BUILDING EXTERIOR DEF:Stained/Peeling/Needs Paint (Walls) – L1

18 18 OF 22 INFO:This is the only damage on this building wall. BUILDING EXTERIOR DEF:Stained/Peeling/Needs Paint (Walls) – L1

19 19 OF 22 INFO:This damage was observed on a sample building with no sample units. DEF:Broken/Missing/Cracked Panes (Windows) - L3 BUILDING EXTERIOR CHANGE TO A DUPLEX PICTURE!

20 20 OF 22 INFO:This damage was observed on a sample building with no sample units. DEF:Broken/Missing/Cracked Panes (Windows) – L2 BUILDING EXTERIOR

21 21 OF 22 INFO:This damage was observed on a sample building with no sample units. DEF:Broken/Missing/Cracked Panes (Windows) - L3 Health & Safety - Other/Sharp Edges BUILDING EXTERIOR

22 22 OF 22 INFO: This ground floor bedroom window is one of the two means of egress from this room within a sample building with no sample units. DEF: Security Bars Prevent Egress (Windows) - L3 BUILDING EXTERIOR