Franklin Electric - The Company You Trust Deep Down Provides The Ultimate Protection for Your Pump & Motor! Franklin SubMonitor
2
Franklin Electric - The Company You Trust Deep Down SubMonitor The latest innovation in 3-Phase submersible pump protection… … made by the world leader in submersible motors Franklin Electric
3
Franklin Electric - The Company You Trust Deep Down SubMonitor Applications Designed to protect 3-Phase pump systems rated between 3 and 200 hp. Designed to protect 3-Phase pump systems rated between 3 and 200 hp. Irrigation Irrigation Mining Mining Commercial Commercial Light Industrial Light Industrial
4
Franklin Electric - The Company You Trust Deep Down Benefits: Made by Franklin Electric Made by Franklin Electric Single core focus: The Water Systems Industry Single core focus: The Water Systems Industry Over 50 years of proven experience Over 50 years of proven experience Continuous improvement in Quality, Availability, Service, Innovation and Value Continuous improvement in Quality, Availability, Service, Innovation and Value One model covers all Franklin submersible motors One model covers all Franklin submersible motors SubMonitor Features & Benefits
5
Franklin Electric - The Company You Trust Deep Down Benefits: Clear user interface – 3 lines x 32 characters Clear user interface – 3 lines x 32 characters Very simple set-up: Hz, Amps, Volts Very simple set-up: Hz, Amps, Volts Warranty covers SubMonitor & motor Warranty covers SubMonitor & motor 500+ event fault history capacity 500+ event fault history capacity Motor over-temperature monitoring Motor over-temperature monitoring SubMonitor Features & Benefits
6
Franklin Electric - The Company You Trust Deep Down Benefits: Removable display lead head – mount on panel door Removable display lead head – mount on panel door No external CT or “Loops” required to change amp rating No external CT or “Loops” required to change amp rating Password protection Password protection Motor run-time counter Motor run-time counter 5 language user interface software 5 language user interface software UL 508 Listed UL 508 Listed SubMonitor Features & Benefits
7
Franklin Electric - The Company You Trust Deep Down SubMonitor Features & Benefits Warranty Warranty 3 years on SubMonitor and Subtrol Heat Sensor-equipped Motor installed simultaneously with a lightning arrestor 3 years on SubMonitor and Subtrol Heat Sensor-equipped Motor installed simultaneously with a lightning arrestor
8
Franklin Electric - The Company You Trust Deep Down Protects against Protects against Overload Overload Underload Underload Under/Overvoltage Under/Overvoltage Current Unbalance Current Unbalance Overheated Motor (Subtrol- Equipped) Overheated Motor (Subtrol- Equipped) False Start (Chattering relays) False Start (Chattering relays) Phase Reversal (reverse rotation) Phase Reversal (reverse rotation) SubMonitor Features & Benefits
9
Franklin Electric - The Company You Trust Deep Down One Size Fits All! One Size Fits All! One Unit – no additional components for entire range of voltage and amp ratings One Unit – no additional components for entire range of voltage and amp ratings 5 to 350 amps 5 to 350 amps 190 to 600 volts 190 to 600 volts 3-200 hp 3-200 hp SubMonitor
10
Franklin Electric - The Company You Trust Deep Down Easy Set-up Easy Set-up Simple text in display area Simple text in display area One menu level to set-up motor for commissioning One menu level to set-up motor for commissioning Simple intuitive interactive push/turn knob Simple intuitive interactive push/turn knob SubMonitor
11
Franklin Electric - The Company You Trust Deep Down No Loops! No Loops! Easy to install Easy to install Other products may require looping around the CT to monitor amperages Other products may require looping around the CT to monitor amperages Motor lead wires Motor lead wires pass through the SubMonitor pass through the SubMonitor SubMonitor
12
Wiring
13
Wiring – External Alarm Alarm circuit Alarm circuit Lamp Lamp dialer dialer 115 or 230 Volt Power External Source or Control Power Transformer M1 M2 A1 A2
14
Franklin Electric - The Company You Trust Deep Down Wiring General Panel Configuration General Panel Configuration Alarm Circuit is not represented Alarm Circuit is not represented Contactor M1, M2 SubMonitor Connections To Contactor Coil T1 T2 T3
15
Three-phase panels Surge arrestor Fused disconnect DP contactor SubMonitor Template for SubMonitor display mounting on door
16
Franklin Electric - The Company You Trust Deep Down
17
D3 Service Tool Provides the ability to download data from the SubMonitor and upload that data to a PC Provides the ability to download data from the SubMonitor and upload that data to a PC Software included with D3 Software included with D3 USB Cable Connector provided USB Cable Connector provided Easy to use Easy to use.xls file format for spreadsheet format.xls file format for spreadsheet format
18
Franklin Electric - The Company You Trust Deep Down D3